May 2003
Programming Manual
1 - 427
A
6
-324000
-642-
02 – Release 6.0
May 20
03
*Software Version 2.xx or higher
Tie line Answer
Detect Time Selection
3-17
Specify the duration between the
time when the receiving system
answers and the time when it is
recognized as an answer.
0 ms.
520 ms.
1950 ms.
Tie Line Release
Detect Time Selection
3-18
Specify the duration between the
circuit disconnection detection on
the Tie line on the distant system
side and the time it is recognized
as Tie Line Release.
0 ms.
520 ms.
1950 ms.
Tie Line/CO/PBX
Incoming Signal
Detect Time Selection
3-19
Specify the time between the
detection of an incoming signal
from another Xen system and the
time when the acknowledgment
signal is sent (Expressed as Wink
Start/Delay/COI in ms.).
0/0/5
520/120/200
1950/450/
800
Tie Line Loop Off-
Guard Time Selection
3-20
Assign loop off-guard protection to
prevent noise that may cause the
system to be unable to answer an
incoming Tie line.
0 sec.
2 sec.
13 sec.
Tie Line Length of
Wink Signal Selection
3-21
Specify the time between the
incoming signal detection from
another Xen system and when the
acknowledgment signal is sent out.
30 ms.
180 ms.
480 ms.
Tie Line Length of
Delay Signal
Selection
3-22
Specify the time a delay pulse is
sent to another system.
0 ms.
300 ms.
4500 ms.
Tie Line Incoming
Interdigit Timeout
Selection
3-24
Specify the maximum time during
the incoming call detection
process. If an address signal is not
received within a specified time, an
error tone is returned to the other
system.
1 sec.
6 sec.
No Limit
Tie Line Wink/Delay
Signal Detect Timeout
Selection
3-25
Specify the maximum time for
receiving an acknowledgment
signal from a distant system before
sending a busy tone.
1 sec.
7 sec.
No Limit
Disconnect
Recognition Time
Selection
3-33
Specify a minimum time for a
disconnected circuit to be
accessed again.
0 sec.
0.3 sec
1.5 sec.
DIT Delay Answer
Timer Selection
3-61
This Memory Block is used to
specify the time and incoming CO/
PBX call will ring before changing
to DIT.
0 sec.
5 sec.
60 sec.
Table 1-6 Function Timer Chart (Continued)
Timer
Memory
Block
Definition
Timing Value
Minimum
Default
Maximum