1 - 142
Hookflash End Time Selection
NEC Business Solutions Ltd
Xen Master & Xen Axis
A
6
-324000-
642-
02 - Release 6.0
May 20
03
1-3-06
System Mode
1
Submode
3
Data No.
06
PC Programming
a
+BTI
Hookflash End Time Selection
General Description
Use this Memory Block to specify the maximum hookflash duration from a Single Line
Telephone to receive a second dial tone.
Display
Settings
(Page 1)
LK 1
LK 2
LK 3
LK 4
The shaded area indicates the default setting.
HST = Hookflash Start Time
00
(HST + 0 ms.)
01
(HST + 100 ms.)
02
(HST + 200 ms.)
03
(HST + 300 ms.)
LK 5
LK 6
LK 7
LK 8
04
(HST + 400 ms.)
05
(HST + 500 ms.)
06
(HST + 600 ms.)
07
(HST + 700 ms.).
(Page 2)
LK 1
LK 2
LK 3
LK 4
08
(HST + 800 ms.)
09
(HST + 900 ms.)
10
(HST + 1000
ms.)
11
(HST + 1100
ms.)
LK 5
LK 6
LK 7
LK 8
12
(HST + 1200
ms.)
13
(HST + 1300
ms.)
14
(HST + 1400
ms.)
15
(HST + 1500
ms.)
Programming Procedures
1
Go off-line.
2
Press LK1 + LK3 +
KF
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
Hookflash Start Time Selection
0 6 : F L S H
E N D = 0 1 | 1
T I M E
D I S P L A Y
Setting
Data
Title
Data
No.
Page
No.