1 - 356
Extension Line Key Ring Assignment (Day Mode)
NEC Business Solutions Ltd
Xen Master & Xen Axis
A
6
-324000-
642-
02 - Release 6.0
May 20
03
The shaded area is the default setting.
4-37
System Mode
4
Submode
—
Data No.
37
PC Programming
a
+BTM
Extension Line Key Ring
Assignment (Day Mode)
General Description
Use this Memory Block to specify the ringing assignment on incoming calls to a Secondary
Incoming Extension (SIE) or a Call Arrival key.
Display
Settings
Page 1 (Line Keys 01~08)
LK 1
LK 2
LK 3
LK 4
There is no default setting.
1
2
3
4
LK 5
LK 6
LK 7
LK 8
5
6
7
8
Page 2 (Line Keys 09~16)
LK 1
LK 2
LK 3
LK 4
9
10
11
12
LK 5
LK 6
LK 7
LK 8
13
14
15
16
Page 3 (Line Keys 17~24)
LK 1
LK 2
LK 3
LK 4
17
18
19
20
LK 5
LK 6
LK 7
LK 8
21
22
23
24
Programming Procedures
1
Go off-line.
2
Press LK4 +
CG
to access the Memory Block.
3
Use the dial pad to select option.
The LED indication changes to indicate data each time a CO/PBX line key is
pressed.
Note:
Use the following to enter data:
S
go to next page
T
go to previous page
R
to select next Tel Port No.
Default Values
All Telephones: No Ring
4
Press
N
to write the data.
5
Press
P
to go back on-line.
0 1 / 3 7 : E X T
D A Y | 0 1
T I M E
D I S P L A Y
Data
No.
Tel Port No.
(01~99)
A0~C0
Title
Page
CO/PBX
Line Key LED
Off
Green
Red
Data
No ring
Immediat
e Ring
Delayed
Ring