Function Specification
117
3.8.2.
Restore Setting Values
This product will restore the setting value from the USB storage connected to a USB port and restarts when the
following conditions are satisfied:
[Restore condition]
Device startup after initialization
Files are saved under the USB storage (SA3500G_config.bin or SA3500G_config.bin.bak).
Setting values saved on the device with earlier firmware version than the version of this product.
[Restore from USB storage procedure]
When restoring setting value to an initialized device.
1. Turn off the device.
2. Connect the USB storage with the setting value stored in the USB port.
3. Turn on the device.
4. The setting value is restored from the USB storage during device start up.
5. When setting value restoration is successful, the OPT2 lamp flashes green.
When restoring setting value to an uninitialized device.
1. Mount the USB storage where setting value is saved on USB port, then OPT2 lamp flashes orange.
2. Initialize setting value (refer to section 5.6.13), then system restarts.
3. The setting value is restored from the USB storage during device start up.
4. OPT2 lamp flashes green when the setting value is successfully restored.
*If OPT2 lamp does not flash green, please check [Restore condition] and [USB Device Requirements] (refer to
section 3.8).
[Note]
Confirm whether or not the setting values were successfully restored with the OPT2 lamp.
[Caution]
When this product is initialized with the connected USB storage device where the setting values are saved, the setting
values are restored from the USB storage after restarting this product. Remove the USB storage before initializing this
product.
Restoring setting values saved on the device with newer firmware version than the version of this product is not
possible.