18
© by NECTA VENDING SOLUTIONS SpA
01-2003 197 00
PROGRAMMING THE BASIC COIN
AND THE DECIMAL POINT
When the “Basic coin / DP” (basic coin value) function from
the “programming” menu is displayed, the value of the
basic coin as well as the position of the decimal point can
be modified.
Press the confirm button “ ” from the “programming”
menu to display the current value of the basic coin.
Using the “ ” and “ ” buttons, the value of the basic coin
and the number of the decimal point position “dP” are
displayed alternately, i.e:
0
decimal point disabled
1
XXX.X
2
XX.XX
3
X.XXX
Press the change button “ ”, these values will start
blinking and can then be modified as necessary.
PAYMENT SYSTEMS
When the “Payment system” function is displayed, it is
possible to define which payment system with Executive
communication protocol to use, selecting among:
Validator
Totalizer
Executive standard
Executive Price Holding
Executive UKEY
Executive ECS
In order to install payment systems different from a
validator or cashless system, special kits must be
used.
The payment systems must be housed in the cabinet
(optional).
PROGRAMMING THE VALIDATOR
If the selected payment system is a validator, its operating
parameters must be defined.
CREDIT CONTROL
It is possible to decide whether any excess credit paid is
to be cashed or made available to the user.
OPERATING VOLTAGE
According to the type of validator it necessary to select the
operating voltage, 12 V or 24 V.
VALIDATOR LINES
When the “Validat. Lines” (line setting) function is dis-
played, the value of the 6 validator coin lines can be
changed.
The value of the lines is indicated as number of basic
coins.
Press the confirm button “ ” from the “programming”
menu to access the line list, which can be scrolled with the
“ ” and “ ” buttons.
When pressing correction button “ ”, this value will start
blinking and can be modified as necessary.
INITIALISING
When the “Initialising” function is displayed the vending
machine can be initialized restoring all default data.
This function should be used if there is a memory data
error or when the EPROM is replaced.
All statistic information will be reset.
Press confirm button “ ” and the display will indicate the
message “Confirm?”. Press the button “ ” again to display
the first variable parameter to define the machine configu-
ration.
The available options (blinking) can be scrolled with the
“ ” and “ ” buttons, the selection is confirmed with button
“ ” and the next parameter is presented. When pressing
button “ ” after the last parameter the display will show the
message “Working” for a few seconds and the machine is
initialised.
The parameters are as follows:
“Machine type”
C -
Espresso
I
-
Instant
“Country”
Type of doses to be
used for the selections
“Layout”
Layout of containers and
selection menu from the
available ones
“Tank”
Water supply from the mains
or from a tank
SETTING THE MACHINE CODE
When the “Machine code” function is displayed the iden-
tification code number of the machine can be changed
(from the default 0000 to 9999).
Press the confirm button “ ” and the current code number
is displayed; then press the correction button “ ” and the
first digit will start blinking.
The value of the blinking digit can be increased or de-
creased with the “ ” and “ ” buttons.
When pressing the confirm button “ ”, the blinking digit
will take on the displayed value and the next digit starts
blinking.
Summary of Contents for Colibri
Page 2: ......
Page 4: ......
Page 40: ...Sx35401...
Page 41: ...Colibr Espresso...
Page 42: ...Sx35600 Sx35600...
Page 43: ...Colibr Colibr Instant Instant...
Page 44: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 45: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 46: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 48: ......