25

3.1.5 - PHOT.ERR.COUNTER

3.1.6 - MOT.ERR.COUNTER

3.2 - STATiSTiCS RESET

3.2.1 - PARTiAL RESET

3.2.1.1 - SELE.COUNT.RESET

3.1.5  

d

IsPlayIng

 

the

 

Photocell

 

error

 

counters

This function is used for displaying the value of the counter regard-

ing the photocell errors.

3.1.6  

d

IsPlayIng

 

the

 

motor

 

error

 

counters

This function is used for displaying the value of the counter regard-

ing the motor errors.

3.2  

d

eletIng

 

the

 

statIstIcs

3.2.1  

P

artIal

 

delete

3.2.1.1  

d

eletIng

 

the

 

selectIon

 

counters

When confirming this function, the counters regarding the different 

selections are deleted.

3.2.1.2 - fAiLURE COUNT.

3.2.1.3 - COiN MECH DATA

3.2.1.4 - CANC. PHOT. ERR.

3.2.1.5 - CANC.MOT.ERR.CNT

3.2.2 - TOTAL RESET

3.2.1.2  

d

eletIng

 

the

 

faIlure

 

counters

When confirming this function, the counters regarding the different 

failure are deleted.

3.2.1.3  

d

eletIng

 

the

 

coIn

 

mechanIsm

 

data

When confirming this function, the counters regarding the coin 

mechanism data are deleted.

3.2.1.4  

d

eletIng

 

the

 

Photocell

 

error

 

counters

When confirming this function, the counters regarding the photocell 

errors are deleted.

3.2.1.5  

d

eletIng

 

the

 

motor

 

error

 

counters

When confirming this function, the counters regarding the motor 

errors are deleted.

3.2.2  

t

otal

 

delete

When confirming this function, all counters regarding the coin 

mechanism data are deleted.

Summary of Contents for Rondo

Page 1: ...PROGRAMMING MANUAL Code Date P2125EN00 English 01 2008 Rondò ...

Page 2: ......

Page 3: ...scribes the Technician Menu the programming part that is meant for technical personnel used for changing the machine performance The operations described can modify the functioning cycles therefore they must be carried out only by per sonnel who have the specific knowledge of the machine functioning from a point of view of electrical safety and health regulations The appendix contains the List of ...

Page 4: ...re or malfunction that did not permit the correct dispensing of the product VENDING MACHINE OUT OF ORDER It is not possible to make selections Besides this message the failure that caused this condition is displayed alternating Suspended servICE It is not possible to make selections This condition occurs when the machine is in Energy Saving mode or while dispensing a prod uct from the slave machin...

Page 5: ...sed for surfing through the different menus Scrolling buttons UP and DOWN The UP and DOWN scrolling buttons are used for moving from one programming menu item to the next one located in the same level and at the same time change the status or the numeric value of the corresponding functions Confirm Enter button The confirm enter key is used for moving to the lower level or for confirming a value a...

Page 6: ...unters regarding the different time bands are printed 1 1 1 3 Printing the failure counters When confirming this function the counters regarding the different failure are printed 1 1 1 4 Printing the coin mechanism data When confirming this function the counters regarding the coin mechanism data are printed 1 1 1 5 Printing the photocell errors When confirming this function the counters regarding ...

Page 7: ...ding the different time bands are printed 1 2 1 3 Printing the failure counters When confirming this function the relative counters regarding fail ures are printed 1 2 1 4 Printing the coin mechanism data When confirming this function the relative counters regarding the coin mechanism data are printed 1 2 1 5 Printing the photocell errors When confirming this function the relative counters regardi...

Page 8: ... total counters regarding each selection 1 3 2 Displaying the time band counters When selecting the desired price band 0 1 2 3 4 Free Test the total number of selections made for that price band is displayed 1 3 3 Displaying the failure counters This function is used for displaying the number of times each pos sible failure occurred in the vending machine 1 3 4 Displaying the coin mechanism data 1...

Page 9: ...ers regarding each selection divided by price band 0 1 2 3 4 Free Test 1 4 1 2 Displaying the total counters This function is used for displaying the total counters regarding each selection 1 4 2 Displaying the time band counters When selecting the desired price band 0 1 2 3 4 Free Test the total number of selections made for that price band is displayed 1 4 3 Displaying the failure counters This ...

Page 10: ...ins inserted in the vending machine differentiated by the type of coin 1 4 4 2 Displaying the cashed amount This function is used for displaying the value of Total cashed Total sold Total cashed by credit 1 4 5 Displaying the photocell error counters This function is used for displaying the value of the counter regard ing the photocell errors 1 4 6 Displaying the motor error counters This function...

Page 11: ...irming this function the counters regarding the coin mechanism data are deleted 1 5 1 4 Deleting the photocell error counters When confirming this function the counters regarding the photocell errors are deleted 1 5 1 5 Deleting the motor error counters When confirming this function the counters regarding the motor errors are deleted 1 5 2 Total delete When confirming this function all relative st...

Page 12: ...and 3 2 2 Price band 4 This function is used for setting a different price for each selection in time band 4 3 tube control 3 1 Filling tube 3 2 TUBE EMPTYING 3 Change tubes control 3 1 Filling the change tubes From this function the change tubes can be filled manually Confirming the refilling the display will indicate Credit which is the value of money available in change the tubes insert the des...

Page 13: ...dispensing long shaped products can be combined specifying the selection number of the second motor The first motor number will be the selection number while the selec tion number of the associated motor will remain disabled 4 4 Photocell parameters The vending machine can be fitted as standard feature or as op tional according to the model with a device that detects the pas sage of dispensed prod...

Page 14: ...ssed and awaits the actuation before going to the next button Temperature test the machine will display the value of temperature detected by the probe In the event of interruption the value 11 0 is displayed in the event of short circuit the value 41 0 is displayed Buzzer test the machine will emit a series of test sounds Compressor test the compressor is activated deactivated using the and button...

Page 15: ...ting the pre alarm counters With this function the counters that control the pre alarms are reset 7 EVADTS 7 1 Connection This function places the machine in wait mode for connection to retrieve data 6 GSM 6 1 RESET PRE AL CNT 7 EVADTS 7 1 Connection ...

Page 16: ...the is more than 1 motor errors at the same time scrolling between errors is automatic 1 4 motors STATUS 1 4 Motors status This function is used to read the last failure that occurred in each spiral even if the machine configuration has an empty position A motor can be in one of the following conditions motor functioning motor not present when the motor is not detected at machine power on motor di...

Page 17: ...me price for all selections or for the single selections 2 1 1 1 Setting single prices 2 1 1 1 1 Price band 0 This function is used for setting a different price for each selection for time band 0 2 1 1 1 2 Price band 1 This function is used for setting a different price for each selection for time band 1 2 1 1 1 3 Price band 2 2 1 1 1 3 Price band 2 This function is used for setting a different p...

Page 18: ...nd 0 2 1 1 2 2 Price band 1 This function is used for setting a single price for all selections avail able in time band 1 2 1 1 2 3 Price band 2 This function is used for setting a single price for all selections avail able in time band 2 2 1 1 2 4 Price band 3 This function is used for setting a single price for all selections avail able in time band 3 2 1 1 2 5 Price band 4 2 1 1 2 5 Price band ...

Page 19: ...nning and end time by hours 00 to 23 and minutes 00 to 59 If the values for start and end of the time band are set to 00 00 the time period is disabled 2 1 1 3 Time BANDS 2 1 1 3 1 SET DATE TIME 2 1 1 3 Time bands Four programmable time bands are provided for selling products at different prices Time band 0 is not programmable and covers the 24 hours 2 1 1 3 1 Set Date and Time This function is us...

Page 20: ...unction is valid only in the case where a change giver coin mechanism is installed in the machine Normally the amount for a selection is cashed after the machine sends the message Selection successful consequently the change is returned at the end of dispensing the selected product By enabling this function disabled by default the cashed signal is sent at the beginning of dispensing consequently t...

Page 21: ... virtual selections this function is used for setting whether to keep OFF or not ON the partial amount should the second selection dispensing fail 2 1 4 4 SFERA TYPE 2 1 4 4 Sfera type In the event of 2 or more Sfera Rondò vending machines connect ed in a bank with this function it is possible to define the Master slave hierarchic order between the vending machines of the same type assigning to ea...

Page 22: ...other payment systems it can be decided whether or not return the entire amount 2 2 1 4 Two motor selections In order to dispense long shaped products dividers can be fitted so that two motors spirals can be used for each single selection With this function the simultaneous operation of two motors can be combined specifying the selection number of the second motor The first motor number will be th...

Page 23: ...ing to the model with a 5 button keypad to which allocate a group of selection With this function it is possible to enable the operation of these selection buttons 2 2 2 2 Setting direct selections With this function it is possible to allocate a group of selections to each direct selection button by specifying the start and end num bers of the series The selections as long as in a sequence can be ...

Page 24: ...2 3 Dispensing compartment lock parameters 2 2 3 1 Operating mode The dispensing compartment can be fitted as standard feature or as optional according to the model with a lock device This function is used for deciding whether leaving the dispensing compartment always free or unlock it with dispensing 2 2 3 2 Unlock time With this function it is possible to program the time 1 minute min to 10 minu...

Page 25: ...according to the relative humidity and the frequency of door openings With the timing set to 0 the function is disabled 2 3 3 Enabling the cooling unit With this function the cooling unit operation can be disabled After modigying this setting the change will apply when restarting the machine 2 3 4 Enabling the food control The machine can be pre set for handling the dispensing of refriger ated foo...

Page 26: ... normal vending mode The following information can be displayed Internal temperature default Time 2 4 3 Promotional message 2 4 3 2 SET PROM ADVERT 2 4 3 1 ENABLE PROM ADV 2 4 3 2 Setting the promotional message This function is used for writing the 4 line promotional message by pressing the confirm button the first character starts blinking this can then be changed using the and buttons scrolling...

Page 27: ...changed messages are still stored 2 4 4 2 Programming the customized strings With this function it is possible to change the messages by press ing the confirm button the first character starts blinking this can then be changed using the and buttons scrolling through the available characters Once the message is completed it can be stored by pressing button 2 4 5 countER at start 2 4 6 CONTRAST CONT...

Page 28: ...unction disabled by default it is possible to suspend vending in certain hours 2 switch off time bands can be programmed 2 5 3 Filler menu masking With this function it is used possible to determine the Filler menu items to be left active or to be disabled ON OFF Statistics Single Prices Tubes control Special selections Test GSM EVADTS The numeric reference of the menu items remains unchanged even...

Page 29: ...unters regarding each selection 3 1 2 Displaying the time band counters When selecting the desired price band 0 1 2 3 4 Free Test the total number of selections made for that price band is displayed 3 1 3 Displaying the failure counters This function is used for displaying the number of times each pos sible failure occurred in the vending machine 3 1 4 Displaying the coin mechanism data 3 1 4 1 AU...

Page 30: ...he different selections are deleted 3 2 1 2 FAILURE COUNT 3 2 1 3 COIN MECH DATA 3 2 1 4 CANC PHOT ERR 3 2 1 5 CANC MOT ERR CNT 3 2 2 TOTAL RESET 3 2 1 2 Deleting the failure counters When confirming this function the counters regarding the different failure are deleted 3 2 1 3 Deleting the coin mechanism data When confirming this function the counters regarding the coin mechanism data are deleted...

Page 31: ...ng the total counters regarding each selection 3 3 2 Displaying the time band counters When selecting the desired price band 0 1 2 3 4 Free Test the total number of selections made for that price band is displayed 3 3 3 Displaying the failure counters This function is used for displaying the number of times each pos sible failure occurred in the vending machine 3 3 4 Displaying the coin mechanism ...

Page 32: ...statistics 3 4 1 Partial delete 3 4 1 1 Deleting the selection counters When confirming this function the counters regarding the different selections are deleted 3 4 1 2 Deleting the failure counters When confirming this function the counters regarding the different failure are deleted 3 4 1 3 Deleting the coin mechanism data When confirming this function the counters regarding the coin mechanism ...

Page 33: ... 2 Printing the time band counters When confirming this function the counters regarding the different time bands are printed 3 6 1 3 Printing the failure counters When confirming this function the counters regarding the different failure are printed 3 6 1 4 Printing the coin mechanism data When confirming this function the counters regarding the coin mechanism data are printed 3 6 1 5 Printing the...

Page 34: ...rinted 3 7 1 3 Printing the failure counters When confirming this function the relative counters regarding fail ures are printed 3 7 1 4 Printing the coin mechanism data When confirming this function the relative counters regarding the coin mechanism data are printed 3 7 1 5 Printing the photocell errors When confirming this function the relative counters regarding the photocell errors are printed...

Page 35: ...be pressed and awaits the actuation before going to the next button Temperature test the machine will display the value of temperature detected by the probe In the event of interruption the value 11 0 is displayed in the event of short circuit the value 41 0 is displayed Buzzer test the machine will emit a series of test sounds Compressor test the compressor is activated deactivated using the and ...

Page 36: ...is function is used for changing the 6 digit numeric code identify ing the group of machines set to 0 by default 5 2 Initialising the data base This function is used for initialising the machine resetting all data to default values This function should be used if there is a memory data error or when the software is replaced Except for the general electronic counter all statistical data is reset Wh...

Page 37: ...on When pressing the confirm button the code is displayed as 0000 regardless of the actual value then by pressing the confirm button the first digit will start blinking Using the scrolling keys its value can be changed during the change operation the value becomes visible Repeat this operation for the 4 digits after which the value is stored and the display will indicate 0000 again 5 3 2 Security ...

Page 38: ...ne indicating the name to be assigned to the file 5 4 1 3 Delete 5 4 1 4 DELETE ALL 5 4 1 3 Delete This function is used for deleting one by one the setup files present in the inserted Up Key 5 4 1 4 Delete all This function is used for deleting all the setup files present in the inserted Up Key 5 4 2 AUDIT MANAGEMENT 5 4 2 Statistics management 5 4 2 1 Vending machine Up Key When confirming this ...

Page 39: ...product after which an ending product pre alarm is signalled via modem 6 2 2 Resetting the pre alarm counters With this function the counters that control the pre alarms are reset 6 2 3 Threshold association This function is used for defining which spirals selections to associ ate to pre alarms for ending product 6 GSM 6 1 GSM PIN CODE 6 2 GSM PRE ALARMS 6 2 1 PRE ALARM THRES 6 2 2 RESET PRE AL CN...

Page 40: ...ked after 5 minutes if the internal temperature sensor is disconnected the display will indi cate a temperature of 11 C The machine is locked after one hour if a sensor short circuit is detected in this case the display will indicate a temperature of 41 C Motor errors With this function the failed motors are displayed for approximately 1 second Scrolling through all failed motors is automatic Note...

Page 41: ...ue Change control This function enables disables the return of credit if no selections are made If enabled this function allows the return of coins even if the first selection was not dispensed If however a selection fails for any reason the change will be returned if requested Maximum credit This function is used to define the maximum accepted credit Maximum change It is possible to set a limit t...

Page 42: ...ng the following functions Type of vending Setting the operating mode for multiple or single dispensing With multiple dispensing the change is not automatically returned after a successful selection however the credit is available for further selections When pressing the coin return button if the function is enabled the available credit is returned up to the maximum change value Obligation to buy ...

Page 43: ...edit excess Credit excess is a credit that cannot be returned to the user for example in the event of failing to return the change due to insufficient minimum level in the tubes If set as MAINTAINED any credit excess remains available to the user If set as CANCELLED it permits to maintain the credit excess for a programmable time before cashing it Cash sale This function is used for setting the ma...

Page 44: ...alue setting must be always greater or equal to the value set with the function Maximum cash revalue in the event it were changed and become lower than such value it will be set automatically to the same value of the Maximum cash revalue Maximum cash revalue This function is used for settino the maximum credit that can be loaded in a cashless system This value cannot be greater than the value set ...

Page 45: ...lity for any inaccuracies due to printing and or typing errors herein contained The instructions drawings and information in general contained in this booklet are of a confidential nature and may not be reproduced entirely or in part or be passed on to a third party without the prior written authorisation of the manufacturer who retains its exclusive ownership ...

Reviews: