![background image](http://html1.mh-extra.com/html/necta/sinfonia-gf6/sinfonia-gf6_user-and-maintenance-manual_3834900006.webp)
Instructions
for Installer,
Maintenance Engineer
and final User
SINFONIA
Rev. 00
H4345 - 00
02/2013
Page 6 of 41
2 MACHINE FEATURES
2.1 Technical Features
MOD. GF6-DR6
Dimensions
GF6
DR6
Height (A) with feet
1830mm
1895mm
Height (A) with leveling screws
1765mm
1830mm
Width (C)
950mm
Depth (B) STD door / Flat door
860 / 845 mm
Weight
290kg
297kg
Electric features
Nominal tension
230 V
Nominal frequency
50 Hz
Installed electric power
850W
Cooling unit
Compressor
(12.11CC) cm³
Refr. Power
1058W
Working range
18 ÷ 32°C 65% R.H.
Settable temperature range
1°C
÷ 25°C
Refrigerant
R404A
Load
0,360 Kg
Expansion direct with capillary
Cooling forced circulation by means 3 fans
FIG. 2.1
MOD. GF9-DR9
Dimensions
GF9
DR9
Height (A) with feet
1830mm
1895mm
Height (A) with leveling screws
1765mm
1830mm
Width (C)
1220mm
Depth (B) STD door / Flat door
860 / 845 mm
Weight
340 kg
350 kg
Electric features
Nominal tension
230 V
Nominal frequence
50 Hz
Installed electric power
850W
Cooling unit
Compressor
(12.11CC) cm³
Refr. Power
1058W
Working range
18 ÷ 32°C 65% R.H.
Settable temperature range
1°C
÷ 25°C
Refrigerant
R404A
Load
0,360 Kg
Expansion direct with capillary
Cooling forced circulation by means 3 fans
Subject to technical changes!
FIG. 2.2
B
C
A
A
B
C