background image

9

6.2. 

FAN CONTROLLER

Remove the battery cover and batteries. With a small 
screwdriver or equivalent, change the switch setting to be 
the same as that on the remote control receiver.

Replace the batteries and cover, plug in the power lead and 
test the fan with the different frequency setting. If 
interferences are still experienced, repeat the steps with 
another switch setting configuration.

7. 

REPLACEMENT SPARE PARTS LIST

PART

DETAIL

Fire Bricks

4 @ 220 x 175 x 25mm

2 @ 220 x 120 x 25mm

2 @ 270 x 175 x 25mm

2 @ 270 x 85 x 25mm

Brick Retainers

1 @ 533mm

2 @ 120mm

Baffle Plate

494 x 6mm

Door Seal

1610mm x 13mm round

Glass Seal

1360mm 8mm x 3mm

Door Glass

476 x 200 x 5mm pyro ceramic

Ash Plate

272.5 x 5mm

Fan

3 speed

PART

DETAIL

Fan Remote 

Receiver

3 speed

Fan Remote 

Control

3 speed

8. 

WARRANTY

Glen Dimplex Australia Pty. Ltd. warrants this stove to be 
able to operate under normal use and service and within 10 
years from the date of the original purchase on the terms 
herein shall repair or replace without cost to the original 
customer any part thereof which shall be returned to our 
factory, transportation charges prepaid and which our 
inspection shows would prevent operation.

This warranty does not apply to firebricks, brick retainer, 
baffle, door seal, glass, nor discolouration of the surface 
or tarnishing of chrome fittings all of which require normal 
service to maintain them.

Under the terms of this warranty, Glen Dimplex Australia 
Pty. Ltd. assumes no responsibility for the labour costs 
involved in removing or replacing the stove. Nor shall Glen 
Dimplex Australia Pty. Ltd. be liable for any injury, loss, or 
damage (direct, indirect or consequential) arising out of 
the use or inability to use the product, or its removal and 
replacement. All other stove warranties, expressed or 
implied are excluded to the extent possible to law. Any 
claims against Glen Dimplex Australia Pty. Ltd. must be 
brought within Australian Jurisdiction.

Electric fans and any remote sender or transmitter are 
warranted against failure to operate for a period of 1 (one) 
year from original purchase date.

The Retailer does not have the authority to alter this 
warranty.

Summary of Contents for INBUILT

Page 1: ...EFFICIENT WARM FRIENDLY OPERATING INSTRUCTIONS...

Page 2: ...Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA NECTRE INBUILT MK2...

Page 3: ...Flue Draught 4 7 Ash Removal 5 8 Flue Chimney Fire 5 9 Cleaning Paintwork and Glass 5 10 Cleaning the Flue 5 11 Troubleshooting Tips 6 11 1 Glass in Door Blackening 6 11 2 Trouble Starting the Fire 6...

Page 4: ...n approval of the manufacturer Extractor fans or cooker hoods must not be placed in the same room or space as this can cause appliance to emit smoke into the room 1 1 AIR CONTROLS The Nectre Inbuilt M...

Page 5: ...kindling wood in the base of the firebox 2 Open both air controls a top air slide pull spring handle all the way out to the left b bottom air slide slide spring handle across to the left 3 Light the p...

Page 6: ...ve for minimum of 10 minutes to allow the fresh wood to catch 6 After 10 or more minutes the top air slide can be adjusted to the desired heat output setting 6 BURNING TIPS 6 1 FUEL QUALITY Use wood w...

Page 7: ...ose cleaner with a soft cloth Do not use abrasive cleaner or scourer pads 10 CLEANING THE FLUE Check inside of flue prior to each season for any build up of creosote wood tar To do this 1 First remove...

Page 8: ...box 11 3 GLASS CRACKING Do not over tighten the screws on the stainless steel strips that hold the door glass in place Otherwise expansion of the cast iron door may cause the glass to crack MAINTENANC...

Page 9: ...le BAFFLE SUPPORT RODS 3 FITTING NEW DOOR GLASS This task may be easier with the door removed from the appliance and laid horizontally on a work bench To replace the door glass 1 Two stainless steel s...

Page 10: ...fasten latch assembly again Close the door with the door handle to test for any improvement If no improvement remove second washer 6 CHANGE FAN CONTROLLER FREQUENCY The frequency used by the fan remot...

Page 11: ...n shall repair or replace without cost to the original customer any part thereof which shall be returned to our factory transportation charges prepaid and which our inspection shows would prevent oper...

Page 12: ...10 Glen Dimplex Australia Pty Ltd 1340 Ferntree Gully Road Scoresby Victoria 3179 Australia T 1300 556 816 F 1800 058 900 Email sales glendimplex com au www glendimplex com au...