background image

 

4)

 

Flip spark arrestor so that hinge rod is on the right side 
and re-install by repeating steps 2 and 1.  

5)

 

Place spark arrestor stop in its locating hole on the 
opposite side.  

 

 

 

2.4.

 

REPLACING THE FAN 

The fan installed in the N900 Open Fireplace is rated to high 
temperatures, but after years of use it may be necessary to 
replace the fan or its associated receiver.   

 

ONLY REPLACE THE FAN WHILE THE FIREPLACE IS INACTIVE.  

TO REPLACE THE FAN AND/OR RECEIVER 

1)

 

Remove the two halves of the grate.  

2)

 

Remove the firebricks. 

3)

 

Using an M8 hex allen key or hex head socket, 
remove the 4 bolts holding the firebox door in place. 
It may be necessary to apply WD-40 or equivalent 
penetrating oil to loosen the threads. 
(If the bolts don’t want to budge or the head has 
been rounded out, don’t stress. Drill out or grind the 
head off the bolt. The door can still be removed and 
the bolt and nut will be replaced anyway.) 

4)

 

Pull the top end of the firebox door towards you and 
the door should slide up and out.  

5)

 

Remove and replace the 4 U-fasteners which hold 
the door bolts. 

6)

 

Follow the steps below for your applicable model. 

 
FREE STANDING 
 

7)

 

After completing “TO REPLACE THE FAN AND/OR 
RECEIVER” steps 1-6, complete the below steps. 

8)

 

To remove the fan receiver, using the 10mm socket, 
undo the 2 nuts holding the receiver cover to its 
studs. 

9)

 

Again using the 10mm socket, undo the 2 adjacent 
nuts holding the fan receiver to the rear assembly. 

10)

 

Unplug the 2 wiring connectors for the receiver and 
pull the fan receiver towards you to slide off the 
studs. 

11)

 

To remove the fan ducting above the fan, use a 
10mm socket and undo the two nuts on the same 
studs that the fan receiver was on. 

12)

 

To remove the fan, undo the 1 nut holding it 
adjacent to the fan receiver bottom stud using a 
10mm socket.  

13)

 

Unplug the 1 wiring connector for the fan and pull 
the fan assembly towards you to slide off its stud.  

14)

 

Reverse steps to reinstall the fan assembly and fan 
receiver.  

 

INSERT/INBUILT 
 

7)

 

After completing “TO REPLACE THE FAN AND/OR 
RECEIVER” steps 1-6, complete the below steps. 

8)

 

To remove the fan ducting above the fan, use a 
10mm socket and undo the two nuts. 

9)

 

To remove the fan, undo the 1 nut holding it 
adjacent to the fan receiver bottom stud using a 
10mm socket. (Pull the fan housing off its stud, 
lifting up and out to remove the assembly, unplug 
the 1 wiring connector.) 

Summary of Contents for N900

Page 1: ...tre N900 Operating Instructions Keep these instructions for future reference Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA Free Standi...

Page 2: ...T USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING WARNING DO NOT STORE FUEL WITH...

Page 3: ...ng instructions below along with diagrams to open and close the damper 1 To open the damper use the tool to push in the adjustment cog and turn to the left until you feel it lock into place 2 To close...

Page 4: ...orous fumes will be given off as the paint cures Do not touch the paint work while it is curing otherwise it can leave a permanent mark on the appliance Keep the room well ventilated until these fumes...

Page 5: ...ent draught suction in the appliance to ensure the fire keeps burning Draught is caused by the rising hot air in the flue when the fire has been lit The position height and size of the flue can affect...

Page 6: ...brush and drop the rope down the flue from outside on top of the roof 4 Grab the end of the rope from inside the firebox and pull the brush down through the flue 5 Check the inside of the flue with th...

Page 7: ...od Remove these using a 10mm socket and 10mm spanner 4 Remove the damper plate and replace with new one TO REMOVE THE DAMPER ROD If the damper rod requires replacing as well follow these steps 1 Remov...

Page 8: ...STOR WHILE THE FIREPLACE IS INACTIVE TO FLIP THE ORIENTATION OF THE SPARK ARRESTOR 1 Lift spark arrestor up until the bottom of the hinge rod becomes free of its locating hole 2 Angle bottom edge out...

Page 9: ...s below for your applicable model FREE STANDING 7 After completing TO REPLACE THE FAN AND OR RECEIVER steps 1 6 complete the below steps 8 To remove the fan receiver using the 10mm socket undo the 2 n...

Page 10: ...rd to remove exposing the receiver 11 Pull the receiver assembly through the cut out in the rear panel and unplug the 2 wiring connectors 12 Reverse steps to reinstall the fan assembly and fan receive...

Page 11: ...10 INSERT INBUILT FAN AND RECEIVER REMOVAL Numbers correspond to steps in Section 2 4...

Page 12: ...67 Damper Handle Fire poker 109 028 Damper Bolts Nuts N920 016 Damper Cog Grub Screw N920 055 Damper Rod Washers N920 057 Damper Cog 109 022 Damper Spring 109 026 Damper Rod 109 025 Damper Plate 109 0...

Page 13: ...Glen Dimplex Australia Pty Ltd 1340 Ferntree Gully Road Scoresby Victoria 3179 Australia T 1300 556 816 F 1800 058 900 Email sales glendimplex com au...

Reviews: