CONTENTS 

INSTALLATION ........................................................................... 1

 

1.

 

IMPORTANT INFORMATION ............................................. 1

 

2.

 

FREE STANDING INSTALLATION ........................................ 2

 

2.1.

 

POSITIONING THE OPEN FIREPLACE ........................ 2

 

2.2.

 

OPTIONAL FREE STANDING BASE ............................ 2

 

2.3.

 

STANDARD INSTALLATION....................................... 2

 

2.4.

 

CORNER INSTALLATION ........................................... 3

 

2.5.

 

CLEARANCE DIMENSIONS ........................................ 3

 

2.6.

 

FLOOR PROTECTOR ................................................. 3

 

2.7.

 

REDUCING CLEARANCES TO COMBUSTIBLES .......... 4

 

2.8.

 

INSTALLING THE FLUE .............................................. 4

 

3.

 

BUILT-IN INSTALLATION .................................................... 5

 

3.1.

 

CLEARANCES TO COMBUSTIBLE MATERIALS ........... 5

 

3.2.

 

ENCLOSURE CONSTRUCTION (WITH MINIMUM 

CLEARANCES) ........................................................................ 5

 

3.3.

 

ENCLOSURE VENTILATION ....................................... 6

 

3.4.

 

FLOOR PROTECTOR (HEARTH) ................................. 6

 

3.5.

 

INSTALLING THE FLUE .............................................. 7

 

3.6.

 

FITTING RECEIVER FOR REMOTE CONTROL ............. 7

 

3.7.

 

POWER SUPPLY FOR FAN ........................................ 7

 

4.

 

MASONRY INSTALLATION ................................................. 8

 

4.1.

 

CLEARANCES TO COMBUSTIBLE MATERIALS ........... 8

 

4.2.

 

FLOOR PROTECTOR (HEARTH) ................................. 8

 

4.3.

 

INSTALLING THE FLUE .............................................. 8

 

5.

 

INSTALLING THE FIREBOX INTERNALS............................... 9

 

6.

 

TECHNICAL DRAWINGS ................................................... 10

 

6.1.

 

FREE STANDING ..................................................... 10

 

6.2.

 

FREE STANDING WITH BASE .................................. 10

 

6.3.

 

BUILT-IN / INSERT .................................................. 10

 

 ........................................................................................ 10

 

 

INSTALLATION 

 

 

1.

 

IMPORTANT INFORMATION 

 

The unit must be installed according to all manufacturers’ 
instructions included in this manual. The manufacturer is not 
liable for installations that do not meet the requirements 
outlined in this manual. 

Most building regulatory authorities in Australia require any 
wood heater installation to comply with Installation Standard 
AS/NZS 2918. Different states and councils may have varying 
regulations. Check local building regulations before installing 
the appliance. 

All Nectre wood heaters have been tested to ensure they will 
meet the appropriate safety standard requirements if the 
instructions in this manual are followed. As the safety and 
emissions performance can be affected by altering the 
appliance, no modifications are allowed without written 
permission from the manufacturer. 

WE RECOMMEND THAT THE INSTALLATION OF YOUR NECTRE 
WOOD HEATER BE CARRIED OUT BY A QUALIFIED INSTALLER. 

WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE 
INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE 
APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING 
CODE OR CODES. 

ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN 
APPROVED IN WRITING BY THE TESTING AUTHORITY IS
 
CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED 
FOR COMPLIANCE WITH AS/NZS 2918 APPENDIX B. 

CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM 
COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING 
THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY 
RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS 
CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED 
IN THE FIRST INSTANCE. 

CAUTION: CRACKED AND BROKEN COMPONENTS, EG. GLASS 
PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION 
UNSAFE. 

 

THE INSTALLATION INSTRUCTIONS IN THIS MANUAL 

APPLY TO THE NECTRE N900 OPEN FIREPLACE MODELS. 

Summary of Contents for N900

Page 1: ...re N900 Installation Instructions Keep these instructions for future reference Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA Free Standing Base Insert ...

Page 2: ... with Installation Standard AS NZS 2918 Different states and councils may have varying regulations Check local building regulations before installing the appliance All Nectre wood heaters have been tested to ensure they will meet the appropriate safety standard requirements if the instructions in this manual are followed As the safety and emissions performance can be affected by altering the appli...

Page 3: ...t section for more detail The height of the open fireplace firebox above the floor can affect the minimum distance the floor protector must extend out in front as well as the materials it is constructed from 2 2 OPTIONAL FREE STANDING BASE The N900 Free Standing model can be purchased with an optional base cabinet floor clearances for this configuration should be followed as per specification To f...

Page 4: ...ox opening 1285mm min overall width and not less than 300mm forward from the front of the open fireplace extending beneath the appliance and not less than 75mm behind 1000mm min overall depth Less than 450mm above the floor two options a Skamotec 225 board 50mm thick board extending not less than 200mm either side of the firebox opening 1285mm min overall width and not less than 500mm forward from...

Page 5: ... protector being not less than 4 6m and the minimum exit height above the roof line of roof ridge as detailed in the AS NZS 2918 The flue kit is supplied with the freestanding open fireplace Note that this flue kit is different to the one supplied with the Built in model of N900 They are not interchangeable The freestanding flue kit consists of 4 x 900mm lengths of 8 inch stainless steel active fl...

Page 6: ... to be installed as tested in accordance with AS NZS 2918 Appendix B The frame is constructed of 90x45mm timber displayed as dashed lines The cladding on the front wall must be a non combustible material with a minimum thickness of 10mm If the cladding is greater than 10mm thick the front edge of the outer skin on the appliance can be adjusted by loosening the screws and the narrow cover on top an...

Page 7: ...K equivalent to compressed fibre cement sheet Base of firebox less than 450mm above the floor Floor protector must extend a minimum 500mm in front of the firebox opening and 200mm either side of the opening It must be constructed from one of two options a Skamotec 225 board 50mm thick b Ventilated floor protector two sheets of 15mm thick compressed fibre cement sheet with a 1mm thick sheet of stee...

Page 8: ...ventilation slots at the bottom Install the remaining inner casing as normal 3 12 inch slotted outer casing the first length of outer casing resting on top of the appliance is the slotted length installed with the ventilation slots at the bottom Install the remaining outer casing as normal All other aspects of the flue kit must be installed in accordance with AS NZS 2918 3 6 FITTING RECEIVER FOR R...

Page 9: ...nce 750 D Distance to side wall 550 Note mantelpiece clearance can be reduced by installing a heat shield beneath it in accordance with AS NZS 2918 4 2 FLOOR PROTECTOR HEARTH The minimum dimensions and construction materials for the floor protector when installed in a masonry fireplace are the same as for a Built In installation Refer to section 3 4 Floor Protector Hearth for details 4 3 INSTALLIN...

Page 10: ...der the retainer allowing the bottom of the brick to sit on the horizontal lower shelf 3 With the bricks installed place the toothed grate lip in the front of the firebox with the Nectre logo on the left side facing out Place the left and right halves of the grate into the fireplace with the front and rear edges resting on the grate lip and rear shelf respectively 4 Slide the ash tray in underneat...

Page 11: ...10 6 TECHNICAL DRAWINGS 6 1 FREE STANDING 6 2 FREE STANDING WITH BASE 6 3 BUILT IN INSERT ...