background image

 

2.4.

 

CORNER INSTALLATION 

 

Dimensions given in the table and image below represent the 
minimum clearance (in millimetres) to combustible materials. 

C = Minimum floor protector depth from door opening 

D = Minimum clearance to ceiling above 

E = Corner clearance 

 

 

2.5.

 

CLEARANCE DIMENSIONS 

 

2.6.

 

FLOOR PROTECTOR 

 

Unless the open fireplace will be standing on a heat resistant 
floor such as concrete slab with slate or tiles, it will be 
necessary to provide a floor protector. 

The minimum required overall dimensions for the floor 
protector are shown in the previous section. 

The construction and dimensions of the floor protector 
depends on the height of the open fireplace firebox above the 
floor: 

450mm or greater above the floor (including being installed 
on base cabinet) – floor protector constructed from minimum 
5mm thick non-combustible material with a thermal 
conductivity not greater than 0.33W/m °K, equivalent to 
compressed fibre cement sheet. The floor protector must 
extend not less than 200mm either side of the firebox opening 
(1285mm min. overall width), and not less than 300mm 
forward from the front of the open fireplace, extending 
beneath the appliance, and not less than 75mm behind 
(1000mm min. overall depth). 

Less than 450mm above the floor – two options: 

a)

 

Skamotec 225 board – 50mm thick board, extending not 
less than 200mm either side of the firebox opening 
(1285mm min. overall width), and not less than 500mm 
forward from the front of the open fireplace, extending 
beneath the appliance, and not less than 75mm behind 
(1200mm min. overall depth). 

b)

 

Ventilated floor protector – two sheets of 15mm thick 
compressed fibre-cement sheet with a 1mm thick sheet 
of steel between them, spaced off the floor with 25mm 
high non-combustible spacers such as RHS square tubing, 
or equivalent, with a minimum ventilation of 2500mm

2

 

at each end between the spacers. Minimum dimensions 
overall as above – 1285mm wide x 1200mm deep 
extending not less than 500mm in front of the open 
fireplace. 

Non-combustible tiles may be laid over the top of either floor 
protector. 

 

For more details and variations on floor protectors refer to 
AS/NZS 2918 Clause 2.2, 3.3.1, & 3.3.2. 

Model 

Free Standing   500 

100 

500 

1300 

25 

Free Standing  

with Base 

500 

100 

300 

1300 

25 

Summary of Contents for N900

Page 1: ...re N900 Installation Instructions Keep these instructions for future reference Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA Free Standing Base Insert ...

Page 2: ... with Installation Standard AS NZS 2918 Different states and councils may have varying regulations Check local building regulations before installing the appliance All Nectre wood heaters have been tested to ensure they will meet the appropriate safety standard requirements if the instructions in this manual are followed As the safety and emissions performance can be affected by altering the appli...

Page 3: ...t section for more detail The height of the open fireplace firebox above the floor can affect the minimum distance the floor protector must extend out in front as well as the materials it is constructed from 2 2 OPTIONAL FREE STANDING BASE The N900 Free Standing model can be purchased with an optional base cabinet floor clearances for this configuration should be followed as per specification To f...

Page 4: ...ox opening 1285mm min overall width and not less than 300mm forward from the front of the open fireplace extending beneath the appliance and not less than 75mm behind 1000mm min overall depth Less than 450mm above the floor two options a Skamotec 225 board 50mm thick board extending not less than 200mm either side of the firebox opening 1285mm min overall width and not less than 500mm forward from...

Page 5: ... protector being not less than 4 6m and the minimum exit height above the roof line of roof ridge as detailed in the AS NZS 2918 The flue kit is supplied with the freestanding open fireplace Note that this flue kit is different to the one supplied with the Built in model of N900 They are not interchangeable The freestanding flue kit consists of 4 x 900mm lengths of 8 inch stainless steel active fl...

Page 6: ... to be installed as tested in accordance with AS NZS 2918 Appendix B The frame is constructed of 90x45mm timber displayed as dashed lines The cladding on the front wall must be a non combustible material with a minimum thickness of 10mm If the cladding is greater than 10mm thick the front edge of the outer skin on the appliance can be adjusted by loosening the screws and the narrow cover on top an...

Page 7: ...K equivalent to compressed fibre cement sheet Base of firebox less than 450mm above the floor Floor protector must extend a minimum 500mm in front of the firebox opening and 200mm either side of the opening It must be constructed from one of two options a Skamotec 225 board 50mm thick b Ventilated floor protector two sheets of 15mm thick compressed fibre cement sheet with a 1mm thick sheet of stee...

Page 8: ...ventilation slots at the bottom Install the remaining inner casing as normal 3 12 inch slotted outer casing the first length of outer casing resting on top of the appliance is the slotted length installed with the ventilation slots at the bottom Install the remaining outer casing as normal All other aspects of the flue kit must be installed in accordance with AS NZS 2918 3 6 FITTING RECEIVER FOR R...

Page 9: ...nce 750 D Distance to side wall 550 Note mantelpiece clearance can be reduced by installing a heat shield beneath it in accordance with AS NZS 2918 4 2 FLOOR PROTECTOR HEARTH The minimum dimensions and construction materials for the floor protector when installed in a masonry fireplace are the same as for a Built In installation Refer to section 3 4 Floor Protector Hearth for details 4 3 INSTALLIN...

Page 10: ...der the retainer allowing the bottom of the brick to sit on the horizontal lower shelf 3 With the bricks installed place the toothed grate lip in the front of the firebox with the Nectre logo on the left side facing out Place the left and right halves of the grate into the fireplace with the front and rear edges resting on the grate lip and rear shelf respectively 4 Slide the ash tray in underneat...

Page 11: ...10 6 TECHNICAL DRAWINGS 6 1 FREE STANDING 6 2 FREE STANDING WITH BASE 6 3 BUILT IN INSERT ...

Page 12: ...Glen Dimplex Australia Pty Ltd 1340 Ferntree Gully Road Scoresby Victoria 3179 Australia T 1300 556 816 F 1800 058 900 Email sales glendimplex com au ...

Reviews: