20 NED
XCM4040SAT4 UME-0002-04
Table 3-3-1
Camera Link Connector (26-pin MDR Connector) pin assignments
CL1(Base Configuration) CL2(Medium Configuration)
No NAME
No NAME
I/O
1
Inner Shield
14
Inner Shield
2 X0-
15
X0+
Out
3 X1-
16
X1+
Out
4 X2-
17
X2+
Out
5 Xclk-
18
Xclk+
Out
6 X3-
19
X3+
Out
7 SerTC+
20
SerTC-
In
8 SerTFG-
21
Out
9 CC1-
22
CC1+
In
10 CC2+
23
CC2-
In
11 CC3-
24
CC3+
In
12 CC4+
25
CC4-
In
13
Inner Shield
26
Inner Shield
Explanation of Signals
Inner Shield :
Shield cable (GND)
X0+,X0-…X3+,X3- : Data output (Channel Link)
Xclk+,Xclk- :
Clock output for above data output synchronization (Channel
Link)
Y0+,Y0-…Y3+,Y3- : Data output (Channel Link)
Yclk+,Yclk- :
Clock output for above data output synchronization (Channel
Link)
SerTC+, SerTC- : Serial data input (LVDS)
, SerTFG- : Serial data output (LVDS)
CC1+,CC1- :
External synchronous signal input (LVDS)
CC2+,CC2- :
Not in use (LVDS)
CC3+,CC3- :
Not in use (LVDS)
CC4+,CC4- :
Not in use (LVDS)
Camera Link compatible cable
3M :14B26 -SZLB - xxx - 0LC by or equivalent
To avoid uncoupling of the cable connectors during power on, make sure to
clamp them with the locking screws.
Do not unplug the cables while power is being supplied to the camera.
No
NAME No
NAME I/O
1
Inner Shield
14
Inner Shield
2
Y0- 15
Y0+
Out
3
Y1- 16
Y1+
Out
4
Y2- 17
Y2+
Out
5
Yclk- 18
Yclk+
Out
6
Y3- 19
Y3+
Out
7
100
Ω
terminated
20
100
Ω
terminated
8
Open 21
Open
9
100
Ω
terminated
22
100
Ω
terminated
10
100
Ω
terminated
23
100
Ω
terminated
11
100
Ω
terminated
24
100
Ω
terminated
12
100
Ω
terminated
25
100
Ω
terminated
13
Inner Shield
26
Inner Shield