41 NED
XCM4040SAT4 UME-0002-04
Gain-Sensitivity is shown below.
Table 4-10-1 Gain-Sensitivity
Analog Amplifier
Sensitivity
(V/lx
s)
Analog Amplifier
Sensitivity
(V/lx
s)
1
x1.00
0.00dB
70
12
x3.74
11.46dB
262
2
x1.13
1.06dB
79
13
x4.23
12.52dB
296
3
x1.28
2.12dB
89
14
x4.78
13.58dB
334
4
x1.44
3.18dB
101
15
x5.40
14.64dB
378
5
x1.63
4.24dB
114
16
x6.10
15.70dB
427
6
x1.84
5.30dB
129
17
x6.89
16.76dB
482
7
x2.08
6.36dB
146
18
x7.78
17.82dB
545
8
x2.29
7.20dB
160
19
x8.79
18.88dB
615
9
x2.59
8.26dB
181
20
x9.93
19.94dB
695
10
x2.92
9.32dB
205
21
x11.22
20.64dB
785
11
x3.31
10.40dB
232
Digital gain x1, Pixel correction: default, (Factory white correction data, Correction level
900DN)
You can choose between Linear or Log mode for the cameras output A/D
Characteristics by sending the “voc” command. The characteristics are
shown in Figure 4-10-2.
Figure 4-10-2 A/D Characteristics
0
50
100
150
200
250
300
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
Amount of Incident Light
Output
LOG ADC