LEGIC Boosters | installation guide
10/18
Data type
Type of transponder data to be read.
+ Unique ID
+ Segment stamp
+ Segment data
Data address
Start address of the first byte to read. Address 0 is the first byte. See also
the 'Stamp length' setting in the search definition for prime transponders.
Data length (in bytes)
Number of data bytes to read.
UID options
UID formatting options: Only when reading Unique ID
+ Alignment left or right
+ Include size
+ ISO14443A reverse byte order (0x11223344 -> 0x44332211)
+ LEGIC Prime format (0x11223344 -> 0x11443322)
Data check
Enable data validation using CRC calculation across the read data (only
for segment data).
+ No CRC check
+ CRC 8 bit (1 byte)
+ CRC 16 bit (2 bytes)
CRC address
Address of CRC when reading data.
CRC options (prime only)
CRC calculation for LEGIC prime transponders coverage.
+ Stamp
+ WRP/WRC/RD
Constant Data
For each data definition optionally 1 or 2 bytes of constant data can be
added. This data can be located before or after the transponder data.