NVITE | installation guide
13/40
3.3
Inputs
The NVITE reader has 3 digital inputs (active low).
Connect to ground to active the input. Leave unconnected otherwise.
Connections
RED/BLUE
Input 0 - LED_UL_IN (active-low)
WHITE
Input 1 - LED_NA_IN (active-low)
BLUE
Input 2 - BEEP_IN (active-low)
BLACK
Ground
SHIELD
Shield connected to DC-ground
STANDARD firmware
The digital inputs can be used to control the LED and buzzer. See details about LED/buzzer control in chapter 4.3.2.
OSDP firmware
The digital inputs are general purpose inputs.
Upon status change the reader will send input status report message OSDP_ISTATR.
The current input status can be requested by sending the input status report request message OSDP_ISTAT.