NVITE | installation guide
17/40
4.2
Options
The options menu gives access to various reader configuration options.
4.2.1
User mode
Select user mode Simple or Advanced to adjust the user interface. User mode Nedap is intended to be used only when
recommended by Nedap. Password is
nvite
.
4.2.2
Send config
Send configuration to reader.
This option will send all configuration settings to the reader and saves them into non-volatile memory of the reader. A
message indicates that the configuration was sent successfully,
4.2.3
Read config
Read configuration from reader.
This option will read all* configuration settings from the reader.
A message indicates that the configuration was read successfully.
* Security keys and passwords cannot be read from the reader
4.2.4
Setup baud rate
Select the serial communication baud rate.
Possible selections are:
1200
2400
9600 (default OSDP)
19200
38400
57600
115200 (default STANDARD)
Click OK after changing the baud rate. Upon success the software will show a message and the baud rate in the
software and reader have been changed. The new baud rate setting in the reader is saved to non-volatile memory.
When using a separate interface converter, it may be required to update the baud rate setting in there as well.
4.2.5
Setup OSDP device address
Select the OSDP device address in range from 0 to 126. Default device address is 0.
4.2.6
Reset config
Reset reader configuration to factory defaults.
All settings will be reset to factory defaults. The reader will restart automatically afterwards.