background image

 

 

 

VP1101-200PM-00 ISO Reader Solid (CAN)

 

Manual version 1.0 / Page 

2

   

 

4 Installation 

4.1 Mounting 

See the relevant equipment manual relating to where the VP1101 is to be installed. (e.g. feeder). 

4.2 Connections 

 

Details VP1101 wiring

 

 

Brown + 

Input voltage 25 VDC, +20% -20% 

White - 

Minus 

Green C

H

 

CAN high 

Yellow C

L

 

CAN low 

Shield 

 

Shielding of CAN-bus cable 

Grey ~ 

Synchronization (antenna) 

Pink ~ 

Synchronization (antenna) 

 

5 Adjustments 

A VP1101 is pre-tuned and ready for use. No antenna adjustments required because of automatic fine 
tuning. 

 

6 Trouble 

shooting 

Errors / malfunctioning are indicated at the controlling computer. 
 

7  Maintenance, cleaning and disposal 

 

Maintenance 

No regular maintenance required. 
 

Software update 

By the CAN bus there is a possibility to update the software. 
 

Cleaning 

A VP1101 can be cleaned with water and sponge. Avoid (aggressive) cleaning liquids.  
 

Disposal 

Discard according to the regulations prevailing at the time of disposal 

 

 

Summary of Contents for VP1101

Page 1: ...Service manual For installation operation and service ISO Reader Solid CAN VP1101 March 2009 Manual version 1 0 ...

Page 2: ...leteness its publication conveys no license under any patent or other right nor does the publisher assume liability for any consequence of its use specifications and availability of goods mentioned in it are subject to change without notice it is not to be reproduced in any way in whole or in part without the written consent of the publisher Nedap N V AGRI P O Box 104 NL 7140 AC GROENLO The Nether...

Page 3: ...1 0 VP1101 ISO Reader Solid CAN Contents 1 Introduction 1 2 Description and functioning 1 3 Safety 1 4 Installation 2 4 1 Mounting 2 4 2 Connections 2 5 Adjustments 2 6 Trouble shooting 2 7 Maintenance cleaning and disposal 2 Appendix A Specifications 3 ...

Page 4: ...VP1101 200PM 00 ISO Reader Solid CAN Manual version 1 0 ...

Page 5: ...dentify tags on ISO frequency 134 2 kHz There are two types FDX HDX or FDX only 3 Safety Installation and service only by trained personnel Always turn off the main power when working on the electrical installation Compliance statement part 15 19 This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada Operation is subject to the following two conditions 1 this device ma...

Page 6: ...enna Pink Synchronization antenna 5 Adjustments A VP1101 is pre tuned and ready for use No antenna adjustments required because of automatic fine tuning 6 Trouble shooting Errors malfunctioning are indicated at the controlling computer 7 Maintenance cleaning and disposal Maintenance No regular maintenance required Software update By the CAN bus there is a possibility to update the software Cleanin...

Page 7: ...work Antennas Internal fixed antenna Detection distance Depending on used tags Synchronization Synchronization according to ISO 11785 ISO 24631 7 Environment Temperature Operating 10 50 C Storage 25 70 C Relative humidity 10 93 non condensing IP class IP 65 Always use a NEDAP power supply The Nedap guarantee regulations are only valid when is installed as indicated in this manual Install data cabl...

Page 8: ......