background image

WIM | INSTALLATION GUIDE 

Plate Conversion Modes

 

 

13/20 

CHAR  TK2 CHARS 

 

CHAR  TK2 CHARS 

 

CHAR  TK2 CHARS 

 

CHAR  TK2 CHARS 

Space  0  0 

  0 

2  0 

 

4  0 

 

6  0 

0  1 

  1 

2  1 

 

4  1 

 

6  1 

0  2 

  2 

2  2 

 

4  2 

 

6  2 

0  3 

  3 

2  3 

 

4  3 

 

6  3 

0  4 

  4 

2  4 

 

4  4 

 

6  4 

%

 

0  5 

  5 

2  5 

 

4  5 

 

6  5 

0  6 

  6 

2  6 

 

4  6 

 

6  6 

0  7 

  7 

2  7 

 

4  7 

 

6  7 

1  0 

  8 

3  0 

 

5  0 

 

7  0 

1  1 

  9 

3  1 

 

5  1 

 

7  1 

1  2 

  : 

3  2 

 

5  2 

 

7  2 

1  3 

  ; 

3  3 

 

5  3 

 

7  3 

1  4 

  < 

3  4 

 

5  4 

 

7  4 

1  5 

  = 

3  5 

 

5  5 

 

7  5 

1  6 

  > 

3  6 

 

5  6 

 

7  6 

1  7 

  ?

 

3  7 

 

5  7 

 

7  7 

Table 3: ISO7811 track 2 character conversion table 

Example 

License plate 'HK55EVB' = B50532525456642F0 
License plate 'VR46IT' = B666224265164F4 

 

ISO7811 track 2 details 

Card loaded, Clock and Data signals are active-low. 
Timing per bit is 630 µsec (= ±1600 Hz). 
The characters are transmitted "backwards". Least significant bit first and ending 
with the odd parity bit. 
Number of leading and trailing clock zeros is 16. 

 

 

odd parity 

msb 

lsb 

210µsec 

5V 

0V 

Clock 

5V 

0V 

Data 

630µsec 

 

 

 

5.6

 

BARCODE WAND EMULATION CODE39 

In this mode the license plate is transmitted in the barcode wand emulation code39 
data format.  
The code39 format is a widely used barcode format. The specification defines that 
the character set includes uppercase letters (A to Z), decimal digits (0 to 9) and a few 
special characters. The asterisk (*) is used for start and stop character. 

 

 
 
 
 
 

Note 

The magstripe iso7811 
track 2 mode does not 
require to use the LAN 
connection. 
 
The magstripe iso7811 
track 2 mode is introduced 
in firmware version 1.05. 

 
 
 
 
 
 
 

Note 

The barcode code39 mode 
does not require to use the 
LAN connection. 
The barcode code39 mode 
is introduced in firmware 
version 1.06. 

 
 
 
 
 
 
 
 
 

Summary of Contents for WIM

Page 1: ...WIM installation guide 2017 01 17 v4 4 5279348...

Page 2: ...PORTS ____________________________________________ 7 5 PLATE CONVERSION MODES ____________________________________________ 8 5 1 WIEGAND 26 BIT SHA 1 _________________________________________ 8 5 2 WI...

Page 3: ...Converts a license plate into a Wiegand output message Output in magstripe or barcode format is also possible Easy integration into existing access control systems Easy user configuration Contains a...

Page 4: ...efore opening the device The WIM shall only be installed and serviced by qualified and trained personnel The WIM can be powered from a low power Class 2 power supply in compliance with local regulatio...

Page 5: ...ata D0 Clock CLS Card Loaded GND Ground BARCODE Barcode wand emulation data output in code39 format Select with the plate conversion mode switches See for more details chapter 5 D1 Wand emulation data...

Page 6: ...e rear panel See the picture below Figure 3 Rear view Power input Use the supplied 24VDC power adapter Power supplies must be able to supply 12 24 VDC 5 Watt positive voltage at center pin Switches Th...

Page 7: ...CTIONS The OCR Read event must generate an RS485 output message as specified below Optionally enable the OCR Not Read event to output a NOTREAD message Optionally enable the OCR No Plate event to outp...

Page 8: ...mode every received license plate message is converted to a Wiegand 26 bit output message using the SHA 1 security hashing algorithm Wiegand 26 bit SHA 1 conversion procedure 1 Receive license plate m...

Page 9: ...010011 D 011101 N 100111 X 110001 4 010100 E 011110 O 101000 Y 110010 5 010101 F 011111 P 101001 Z 110011 6 010110 G 100000 Q 101010 7 010111 H 100001 R 101011 8 011000 I 100010 S 101100 empty 000000...

Page 10: ...ed 133 sec plate max 130 sec x 1008 135msec 8 sec plate max 8 sec x 20480 160msec The match list is managed through the LAN interface This can be done using the WIM_List software See below a screensho...

Page 11: ...ists of 6 data bits 1 odd parity bit for each character See character set below Char Bin Char Bin Char Bin Char Bin Space 000000 0 010000 100000 P 110000 000001 1 010001 A 100001 Q 110001 000010 2 010...

Page 12: ...plate ES LRC Where SS Start sentinel hex B bin 1011 plate License plate string variable number of characters ES End sentinel hex F bin 1111 LRC Checksum Xor all message characters including SS and ES...

Page 13: ...1600 Hz The characters are transmitted backwards Least significant bit first and ending with the odd parity bit Number of leading and trailing clock zeros is 16 odd parity msb lsb 1 1 0 1 0 210 sec 5V...

Page 14: ...e wide and six elements are small The ratio between wide and small is 3 1 The characters are separated by an inter character gap which is a small space Output connection D1 transmits code39 data black...

Page 15: ...erminated with a carriage return 0x0D and linefeed 0x0A character sequence message cr lf Usually the WIM will reply messages with a echo message to indicate that the message was successful If a comman...

Page 16: ...license plate entries Syntax SLSppp wwwwwwwwwwww Reply SLSppp wwwwwwwwwwww MEMFULL Memory full plate not appended PLEXIST Plate already exists plate not updated only match list XL mode Where ppp Lice...

Page 17: ...ch list Syntax SNFwwwwwwwwwwww Reply SNFwwwwwwwwwwww Where ww ww Wiegand output specification used when license plate not found Must be exactly 12 hex characters including a start bit and the complete...

Page 18: ...temperature 0 C 55 C 32 F 130 F Relative humidity 90 non condensing Power supply 12 24 VDC 10 power supply Current consumption 5 Watt Interfaces RS485 License Plate Reader Wiegand Access Controller LA...

Page 19: ...leteness its publication conveys no license under any patent or other right nor does the publisher assume liability for any consequence of its use specifica tions and availability of goods mentioned i...

Page 20: ...ved 4 1 2015 03 23 HR update 4 0 2014 02 26 Layout adjusted to new corporate style 1 3 2013 11 21 Added match list XL 1 2 2012 06 07 Added barcode plate conversion mode 1 1 2012 02 15 Added magstripe...

Reviews: