WIM | INSTALLATION GUIDE
ANPR Configuration
7/20
4
ANPR CONFIGURATION
This chapter describes the required plate reader settings when using the WIM. These
settings must be configured in the plate reader using a web browser and the plate
reader's TCPIP interface. See for more details about the plate reader the ANPR
installation guide.
4.1
PLATE READER SETTINGS
4.1.1
EVENTS / ACTIONS
The OCR Read event must generate an RS485 output message as specified below.
Optionally enable the OCR Not Read event to output a NOTREAD message.
Optionally enable the OCR No Plate event to output a NOPLATE message.
OCR Read – 485 Msg
Enable: YES
Message: %PLATE_STRING%0x0D%0x0A
OCR Not Read – 485 Msg
Enable: YES | NO
Message: NOTREAD%0x0D%0x0A
OCR No Plate – 485 Msg
Enable: YES | NO
Message: NOPLATE%0x0D%0x0A
4.2
SYSTEM SETTINGS
4.2.1
SERIAL PORTS
The RS485 serial port must be enabled as specified below.
Enable:
YES
Baud rate:
9600
Parity:
NONE
Data Bit:
8
Stop Bit:
1
Message:
RAW