FilterCart Carbon
4 Fitting the Fume Extractor hood
The Fume Extractor arm is already fitted. The hood
must be fitted according to the
, items 1–4.
Adjust the links so that the hood can be easily posi-
tioned.
4.1 Initial operation
• Ensure the FilterCart Carbon has not been damaged
during transport.
• Check that the mains voltage is the same as on the
sign plate of the FilterCart Carbon . Connect the con-
nection cable with plug to the mains.
• Start the FilterCart Carbon with the circuitbreaker A
on the controlboard.
4.2 Overload protector
See
. The FilterCart Carbon is equipped with
an overload protector which means that the power
will disconnect automatically if the fan motor is over-
loaded.
The overload protector is easily re-set by the push
button A on the control board.
5 Wiring diagram
See
• M1: Fan motor, 0.55 kW (0.75 hp).
• X1: Terminal block, connection to mains (voltage,
depending on model).
• F1: Circuit switch, overload protector.
6 Directions for use
The FilterCart Carbon is only intended for indoor use.
It is designed for extraction and filtration of odours
and vapours from non-toxic smelling solvents in mod-
erate concentrations. The hood of the extraction arm
should be positioned as close to the pollution source
as possible. The FilterCart Carbon should be moved
from behind according to
wheels unlocked. The extraction arm should be posi-
tioned with the wheels locked according to item B.
WARNING! Risk of personal injury, fire or
explosion
• The product must not be used in an environ-
ment with a danger of explosion or for gases
in explosive concentrations.
• Not to be used for dust or welding fumes.
• Not to be used for extracting toxic sub-
stances.
• Not to be used for extracting odourless sub-
stances.
• Not be used without filter cartridge and cas-
ing.
7 Changing the filter cartridge
. The filter cartridge is disposable and is
to be thrown away after use. The life of the filter cart-
ridge varies greatly depending on how the FilterCart
Carbon is used and how much and what type of pollut-
ants are collected.
Change the filter cartridge when the smell from the
filtrated substances comes through the filter outlet.
Always check that the hoses for the extraction arm
and the fan inlet not are damaged before it is decided
to change the filter cartridge.
WARNING! Risk of personal injury
Use necessary personal safety equipment
when replacing the filter cartridges.
Change the filter cartridge in the following way:
1
Disconnect the mains connection cable.
2
Unlock the eccentric locks and remove the filter
casing.
3
Use the plastic bag which comes with the new fil-
ter cartridge and pull it over the used cartridge.
Fold the plastic bag under the cartridge and close
it with the band supplied.
4
Use a duster to wipe off the filter cartridge con-
tact surfaces in the FilterCart Carbon. Put the
duster in the plastic bag with the filter cartridge
and close the bag with the band supplied.
5
Handle the used filter cartridge according to the
relevant regulations for the substances that have
been collected.
6
Check that the new filter cartridge is not damaged.
Also, check that the seal fitted on the underside
of the cartridge is not damaged. Then fit the cart-
ridge on the FilterCart Carbon.
7
Refit the filter casing. Make sure the eccentric
locks tighten the filter casing properly.
• A. Increasing the locking power.
• B. Decreasing the locking power.
8 Changing the HEPA-filter (access-
ory)
. If the FilterCart Carbon has been sup-
plied with a HEPA-filter, this is to be changed at the
same time as the main filter cartridge is changed.
WARNING! Risk of personal injury
Use necessary personal safety equipment
when changing the HEPA-filter.
Change the HEPA-filter cartridge in the following way:
1
Disconnect the mains connection cable.
2
Unscrew the top cover.
3
Remove the used HEPA-filter and put it in the
plastic bag which comes with the new HEPA filter.
Close the plastic bag with the band supplied.