Cable Reel Series 793
EN
10
2
Safety
This document contains important information that is presented either as a
warning, caution or note. See the following examples:
WARNING!
Risk of personal injury.
Warnings indicate a potential hazard to the health and safety of personnel,
and how that hazard may be avoided.
CAUTION!
Risk of equipment damage.
Cautions indicate a potential hazard to the product but not to personnel, and
how that hazard may be avoided.
NOTE!
Notes contain other information that is important for personnel.
2.1
General
•
In accordance with the European standard the incoming 3-phase supply
should be fitted with a hand operated approved switch that must be
mounted near the Cable Reel. Refer to local and national standards when
located outside of Europe.
•
The continuity of the protective current circuit should be checked before
the Cable Reel is used.
•
Check that the supply voltage and frequency correspond with the data
on the machine plate of the Cable Reel before connecting to the mains
supply.
•
The Cable Reel should be connected to earth by the electrician carrying
out the installation.
•
Work on the electrical equipment may only be carried out by a qualified
electrician.
•
All power conductors and earth conductors should be checked and if
necessary retightened a few months after commissioning to ensure good
contact.
•
Never carry out service work, electrical or mechanical, without
disconnecting the mains voltage using an approved switch. Lock the
switch if necessary.
•
Always replace damaged, worn or defective electrical components or
other parts with new original parts.
3
Description
Dimensions: see figure 1(A). For technical data, see also type label on the
product.
3.1.1
Technical data
For technical data, see also type label on the product.
Table 3-1: Technical data
Voltage
Current
Conductors
Cable length
Power *
230 V
16 Amp.
3 x 2.5 mm2
18 m (59 ft), 25 m (82 ft)
3680 W
Summary of Contents for 793 Series
Page 2: ......
Page 8: ...Cable Reel Series 793 8 X A B C 3 ...
Page 14: ...Cable Reel Series 793 EN 14 ...
Page 20: ...Cable Reel Series 793 DE 20 ...
Page 26: ...Cable Reel Series 793 ES 26 ...
Page 32: ...Cable Reel Series 793 FI 32 ...
Page 50: ...Cable Reel Series 793 NO 50 ...
Page 56: ...Zwijacz przewodu seria 793 PL 56 ...
Page 62: ...www nederman com ...