E-PAK 500
27
EN
NOTE!
National and local electric regulations are to be followed.
For electrical data, see ‘4.3.2 Electrical data’. Column F1 gives the recommended mains fuses
(slow) for different supply voltages.
Column S1F gives the settings for the overload relay. These are set when the unit is tested
before delivery but should be verified when installing the unit. The setting is equivalent to
0.58×the nominal current of the motor.
For the power circuit, control circuit and terminal connection diagrams, see the following
figures:
•
Power circuit diagram
Figure 17.
•
Control circuit diagram
Figure 18.
•
Terminal connection diagram
Figure 19.
7.3.1
General requirements
The following items are minimum requirements to ensure the proper function and required
level of protection with regards to equipment category, the EC directives and standards listed in
Directives:
•
Take proper measures to avoid all types of electrical stray currents to and/or from the duct
system and electrical wiring.
•
Check that the input voltage and frequency to the unit are correct.
•
A lightning conductor is to be installed if the unit is installed outdoors. The installation
of the lightning conductor is to follow national and local regulations for such a protection
device.
7.3.2 Ground check measurement
Check that the unit is properly grounded after both the main installation and regular
maintenance work. If a component is removed and refitted, ground connection is to be verified.
7.4
Compressed air installation
WARNING!
Risk of personal injuries.
Use ear protection and safety goggles!
Requirements
For air consumption, quality and max. and min. pressure, see
Section ‘4.3 Technical and electrical data’.
NOTE!
The specified air consumption of the unit is limited to the short operation of the
cleaning valve.
As new ducts may contain dirt, particles or debris, the compressed air pipe is to be blown clean
before connecting E-PAK 500. A compressed air filter, see Figure 5, item 6, is to be installed
to ensure the reliable and safe operation of the unit. A compressed air valve, that vents the
remaining pressure of the unit, is to be installed, see Figure 5, item 7.
NOTE!
Take measures necessary to avoid water or humidity in the compressed air when the
unit is installed in cold environments.
NOTE!
If antifreeze additives are used, use them continuously. Once added, the removal of the
antifreeze additive may cause the pneumatic components to malfunction.
WARNING!
Risk of personal injuries.
The compressed air valve is to be locked in the closed position during maintenance.
Summary of Contents for E-PAK 500
Page 2: ...E PAK 500 2 ...
Page 8: ...E PAK 500 8 800 mm 3 5 150 mm 6 2 3 4 2 3 1 ...
Page 9: ...E PAK 500 9 4 4 2 5 6 3 7 1 11 12 10 8 9 ...
Page 10: ...E PAK 500 10 5 1 2 3 4 5 6 7 8 667 C C 1174 C C 11 6 ...
Page 11: ...E PAK 500 11 7 8 1 2 4 3 1 13 14 15 3 5 6 7 4 16 8 9 10 11 2 17 12 ...
Page 12: ...E PAK 500 12 0 I RESET MANUAL START MANUAL FILTER CLEANING 9 10 11 ...
Page 13: ...E PAK 500 13 14 15 16 12 13 ...
Page 14: ...E PAK 500 14 17 ...
Page 15: ...E PAK 500 15 18 ...
Page 16: ...E PAK 500 16 19 ...
Page 17: ...E PAK 500 17 20 ...
Page 56: ...E PAK 500 CS 56 SSR Relé pro spuštění a vypnutí ...
Page 385: ...E PAK 500 385 ZH SSR 启动 停止继电器 TS 热控开关 SSR 启动 停止继电器 ...
Page 390: ...E PAK 500 ZH 390 ...
Page 391: ......
Page 392: ...www nederman com ...