Appendix B: Service protocol
Copy the service protocol, fill it in and save it as a service record.
NOTE!
If the results of the checks (for example, measured values) differ significantly from
previous results, investigate more carefully.
E-PAK No.
Date:
Operating hours:
Performed by:
Control items
Result
Result
Result
Result
Inspect/clean outside the unit
Remove dust deposits, clean work area
Remove corrosion by grinding, apply primer and touch up paint
Inspect/clean inside the unit*
Power conductor connections and ground wires, check
Automatic start and stop, check
Automatic filter cleaning, check
Manual filter cleaning, check
Vacuum limiting valve, check
(both, if two are fitted)
Cleaning valve, check
Filter bags, visual check
Filter bags, check pressure drop/performance
Clean and dry air (ISO 8573-1, class 5), check
Ground measurement, check (≤100 ohm):
GND1 – Fan
Ground measurement, check (≤10
5
ohm)
Incoming duct – Incoming mains ground
GND1 – External mains ground
Gaskets, check for leakage and replace, if necessary*
Main filter, replace
Plastic bag, replace
* When replacing filter bags.
Summary of Contents for E-PAK 500
Page 2: ...E PAK 500 2 ...
Page 8: ...E PAK 500 8 800 mm 3 5 150 mm 6 2 3 4 2 3 1 ...
Page 9: ...E PAK 500 9 4 4 2 5 6 3 7 1 11 12 10 8 9 ...
Page 10: ...E PAK 500 10 5 1 2 3 4 5 6 7 8 667 C C 1174 C C 11 6 ...
Page 11: ...E PAK 500 11 7 8 1 2 4 3 1 13 14 15 3 5 6 7 4 16 8 9 10 11 2 17 12 ...
Page 12: ...E PAK 500 12 0 I RESET MANUAL START MANUAL FILTER CLEANING 9 10 11 ...
Page 13: ...E PAK 500 13 14 15 16 12 13 ...
Page 14: ...E PAK 500 14 17 ...
Page 15: ...E PAK 500 15 18 ...
Page 16: ...E PAK 500 16 19 ...
Page 17: ...E PAK 500 17 20 ...
Page 56: ...E PAK 500 CS 56 SSR Relé pro spuštění a vypnutí ...
Page 385: ...E PAK 500 385 ZH SSR 启动 停止继电器 TS 热控开关 SSR 启动 停止继电器 ...
Page 390: ...E PAK 500 ZH 390 ...
Page 391: ......
Page 392: ...www nederman com ...