FilterBox
2 Troubleshooting
2.1 Download error log via USB
1 Open the lid to the control box.
2 Connect a USB memory stick or computer to the FilterBox USB contact, and close the lid to download the er-
ror log.
3 Wait 2 minutes and then open the lid and disconnect the computer, or remove the USB memory stick.
2.2 Update software via USB
Section 2.1 Download error log via USB
2.3 Troubleshooting guide
does not solve the problem, contact your nearest author-
ized distributor or Nederman for technical advice.
If necessary, download the USB error log, see
Section 2.1 Download error log via USB
.
Table 2.1 Troubleshooting guide
Error
Solution
Overload protector is activated. See also the Filter-
Box User Manual.
• Check the power connections.
• Make sure the amperage is set correctly according
to the motor nameplate.
• Check if the rubber springs are in the correct posi-
tion.
Semi-automatic or manual adjustment does not
work.
• Check that the springs are set in the up position.
• Make sure the air cleansing is connected to com-
pressed air at a pressure of 5-8 bar.
The fan will not start.
• Check the power connections.
• Check the fuses.
• Make sure the amps are set correctly according to
the motor nameplate.
• Make sure the fan is connected properly.
The air throughput is limited.
• Make sure the fan rotates correctly.
• See if the filter needs to be cleaned.
• Check if the extraction arm is damaged.
• Check if the hood or the fan inlets and outlets are
blocked.
The LEDs on the control panel are not lit.
Check the connections on the back of the control box.
Problem with compressed air.
• Check for leaks in compressed airlines.
• The compressed air tube is too long.
Collector bin leaks.
• Check that the dust container is mounted correctly.
• Empty the dust container.
The pressure is greater than 2300 Pa, but automatic
cleaning has not started.
Contact Nederman for service.
23
Summary of Contents for FilterBox 12M
Page 4: ...FilterBox Figures FilterBox Basic III 1Phase 110 120 220 240V IEC 1 4 ...
Page 5: ...FilterBox FilterBox Basic III 3Phase 200 240V IEC 2 5 ...
Page 6: ...FilterBox FilterBox Basic III 3Phase 380 420V IEC 3 6 ...
Page 7: ...FilterBox FilterBox Basic III 1Phase 110 120 or 220 240V UL CSA 4 7 ...
Page 8: ...FilterBox FilterBox Basic III 3Phase 208 240V UL CSA 5 8 ...
Page 9: ...FilterBox FilterBox Basic III 3 Phase 440 480 575V UL CSA 6 9 ...
Page 10: ...FilterBox FilterBox Advanced III 1Phase 110 120 220 240V IEC 7 10 ...
Page 11: ...FilterBox FilterBox Advanced III 3Phase 200 240V IEC 8 11 ...
Page 12: ...FilterBox FilterBox Advanced III 3Phase 380 420V IEC 9 12 ...
Page 13: ...FilterBox FilterBox Advanced III 1Phase 110 120 or 220 240V UL CSA 10 13 ...
Page 14: ...FilterBox FilterBox Advanced III 3Phase 208 240V UL CSA 11 14 ...
Page 15: ...FilterBox FilterBox Advanced III 3Phase 440 480 575V UL CSA 12 15 ...
Page 18: ...FilterBox FilterBox Basic III Layout Power Cable Basic IEC UL CSA 15 18 ...
Page 19: ...FilterBox FilterBox Basic III Layout Control Cable Basic IEC UL CSA 16 19 ...
Page 20: ...FilterBox FilterBox Advanced III Layout Dp Hose Advanced IEC UL CSA 17 20 ...
Page 21: ...FilterBox FilterBox Advanced III Wiring IEC UL CSA 18 21 ...
Page 26: ...www nederman com ...