C 25
4
99% or 99,9 % (PTFE-filter) at 0,5 µm (after some time in operation)
4 x 12 = 48 m
2
(Poly Web filter)
4 x 10 = 40 m
2
(Poly Web antistatic filter)
PTFE Impregnated spun bound polyester (PW NS)
PTFE membrane laminated to spun bound polyester (PW PTFE)
Aluminium spun bound polyester (PWA)
Aluminium coated spun bound polyester, laminated with a PTFE membrane. (PWA PTFE)
1500 - 3000 m
3
/h (depending on load and application)
-20 °C to +50 °C
0 °C to +60 °C, not condensing
3 mm painted steel plate
0,4 - 0,6 MPa (4 - 6 bar, 58 - 87 psi), (0,5 MPa rec.), water and oil free
32 N-litres / cleaning pulse at 0,6 MPa (6 bar, 87 psi)
R 1/2" (DN 15)
3 kW (4 hp)
IP 54
24 V AC, maximum 60 VA
0 to -5 kPa, not overpressure
Lp Aeq, 30 s, 50 dB
66 dB(A)
454 kg
Filtration
Filter area
Filter material
Operating airflow
Operating temperature
Process air (dry) temperature
Material description
Compressed air requirements
Compressed air consumption
Compressed air connection
Fan motor
Protection class
Relay voltage, accessory
Working pressure
Pulse noise
Noise level
Weight
TECHNICAL DATA
2163
559
518
20
800
50
Open door
max. 155°
1139
1343
763
1887
Ø315
Ø315
191
803
912
195
1527
Ø315
590
DIMENSIONS
Voltage
208 V 60 Hz 230 V 50 Hz
400 V 50 Hz 460 V 60 Hz 575 V 60 Hz 380 V 60 Hz
Current
11 A
10 A
6.1 A
5 A
4 A
6,1 A
1. Modification Kit 400 to 230V