The LED:s can indicate the following:
1, 2, 3, 4, 5 green fixed light: All functions normal
and correct
1, 2, 3, 4, 5 green fixed light alternating with blinking red:
The system operates. Incorrect function
has been rectified (alarm memory)
1, 2, 3, 4, 5 red fixed light: Incorrect function which
requires investigations.
6 yellow fixed light: Incorrect function which
requires attention.
7 red blinking light: Incorrect function which
requires immediate investigations.
1, 3, 4, 5 is only active after the inputs for the
accessories has been activated
(see page 11).
0
1
0
1
Blinks when the cleaning
function operates.
Fixed light when the
system operates.
1
0
1
0
1
1 2 4
0
1
0
1
r E
0
1
0
1
Both "point" and
1
blinks when cleaning after operation is in progress.
1
The system has stopped and the
cleaning after operation is active.
If the 0/1 button is pressed once
more the cleaning after operation
is stopped immediately.
MONITORING SYSTEM, GENERAL DESCRIPTIONS
The display on the Control Box gives information
about the number of operating hours, cleaning
process, alarm functions and possible faults.
The total number of operating
hours are displayed.
r E
is displayed when trying to stop
the system from the control box when
the system is remote started.
r E
is displayed alternating with the
number of operating hours.