FlexPAK 800/1000
EN
24
6.1.1
Nederman FlexPAK Off (Off mode)
The unit is in Off mode, which is also the unit’s start menu. The unit can also go into Off
mode if something is wrong, such as if an alarm is activated. The pump motor is off, there is
no vacuum, the FCV is closed, and the unit cannot be activated by a pilot signal.
TimeToService: The amount of time until next scheduled service. The
default setting is 2000 hours.
6.1.2
FlexPAK Standby (Standby mode)
The unit is in Standby mode. The pump motor is off, there is no vacuum, the FCV is closed,
and the unit is waiting for a pilot signal to go into Running mode.
ESC
OK
NEDERMAN
FLEXPAK
Standby
Wai
ti
ng For
Pilot Signal
Mo 15:33
6.1.3
Running (Running mode)
The unit in Running mode. The pump motor is on and the unit generates a vacuum. The
FCV is closed. The current vacuum of the unit is shown on the display, for example, -20 kPa.
ESC
OK
Running
kPA -20
DIRTm
00:00 s
OTTmr
00:00 h
Exhaust
Air Temp 60°C
DIRTm: The amount of time before the unit goes into Idling mode. The
default is 10 seconds.
OTTmr: If the Overtime timer has been activated, OTTmr shows the
elapsed time since the overtime timer started.
6.1.4
FlexPAK Idling (Idling mode)
The unit in Idling mode. The pump motor is on, there is no vacuum, and the FCV is open.
The unit goes into Idling mode when there has been no pilot signal for the time set in DIR_
Time.
ESC
OK
FlexPak
Hi Vacuum Unit
IDLING
Time To StandBy
05:33m
TimeToStandby: The amount of time until the unit goes into Standby
mode. The default setting is 12 minutes.
6.1.5
Filter Cleaning
The unit is cleaning its main filter.
ESC
OK
Filter
Cleanining
Cycles
1
Elapsed
0
Clean
00:00 s
Charge
00:00 s
Cycles: How many cleaning pulses will be carried out.
Elapsed: How many cleaning pulses are made.
Clean: Remaining time for cleaning pulse.
Charge: Remaining vacuum build time; the time until cleaning pulse is
activated.
6.2
Warning messages
If a warning is activated, there is a problem that needs to be corrected, but the unit
continues to work. If a warning message is displayed in the PLC display, the light in the
Summary of Contents for FlexPAK 1000
Page 8: ...FlexPAK 800 1000 8 1 2 3 4 5 6 7 14 13 12 11 9 8 10 7 6 ...
Page 10: ...FlexPAK 800 1000 10 9 10 1643 1mm 65 662 1mm 26 2 1771 4 1mm 70 Ø13mm 2 1 4 5 6 8 7 9 3 1 ...
Page 11: ...FlexPAK 800 1000 11 11 12 14 13 ...
Page 12: ...FlexPAK 800 1000 12 1 0m 39 4 A B C 16 17 15 Min 2 1m 83 A A A A C ...
Page 14: ...FlexPAK 800 1000 14 ...
Page 55: ...FlexPAK 800 1000 55 CS ...
Page 76: ...FlexPAK 800 1000 DA 76 ...
Page 97: ...FlexPAK 800 1000 97 DE ...
Page 98: ...FlexPAK 800 1000 DE 98 ...
Page 119: ...FlexPAK 800 1000 119 ES ...
Page 120: ...FlexPAK 800 1000 ES 120 ...
Page 141: ...FlexPAK 800 1000 141 FI ...
Page 142: ...FlexPAK 800 1000 FI 142 ...
Page 163: ...FlexPAK 800 1000 163 FR ...
Page 164: ...FlexPAK 800 1000 FR 164 ...
Page 205: ...FlexPAK 800 1000 205 IT ...
Page 206: ...FlexPAK 800 1000 IT 206 ...
Page 227: ...FlexPAK 800 1000 227 NL ...
Page 228: ...FlexPAK 800 1000 NL 228 ...
Page 270: ...FlexPAK 800 1000 PL 270 ...
Page 292: ...FlexPAK 800 1000 PT 292 ...
Page 314: ...FlexPAK 800 1000 RU 314 ...
Page 335: ...FlexPAK 800 1000 335 SV ...
Page 336: ...FlexPAK 800 1000 SV 336 ...
Page 356: ...FlexPAK 800 1000 ZH 356 ...
Page 357: ......
Page 358: ...www nederman com ...