FlexPAK 800/1000 DX
EN
34
NOTE!
The unit is CE-marked. Connections to the unit, initial start-up and maintenance are
to be carried out according with this manual.
9.1
Service and maintenance of ATEX equipment
To ensure the required level of protection, ensure that the following is performed:
•
FlexPAK 800/1000 DX is regularly inspected for damage or malfunction. If
FlexPAK 800/1000 DX is damaged, it is to be shut down and any explosive atmosphere
removed.
•
There is to be no explosive atmosphere when servicing or inspecting
FlexPAK 800/1000 DX.
•
Only Nederman original spare parts are to be used.
•
FlexPAK 800/1000 DX is not be covered with thick dust layers (>5 mm). This is
prevented by setting up routines for regular cleaning and including these in the
explosion protection document.
9.2
Empty the collector bin
WARNING!
Explosion risk.
Never use the unit without an antistatic plastic bag.
WARNING!
Risk of personal injury.
•
Ensure that there is no vacuum in the dust separator before removing the collector bin.
•
Crush hazard. Be careful when lowering and refitting the collector bin. Use proper
protective equipment.
•
Wear goggles, dust mask and gloves when emptying the collector bin.
CAUTION!
Risk of equipment damage.
Use only Nederman original spare parts and accessories.
NOTE!
The antistatic plastic bag is to be replaced when filled up to 2/3, see figure
To replace the antistatic plastic bag:
1.
Check that the risk area is clear.
2.
Ensure that there is no vacuum in the dust separator.
3.
Remove the collector bin.
4.
Seal and remove the antistatic plastic bag. Use a cable tie or equivalent, see figure
5.
Fit a new antistatic plastic bag in the collector bin.
6.
Refit the collector bin onto the dust separator.
7.
Check that the pressure equalizer hose is attached to the collector bin, see figure
8.
Check that the collector bin seals properly once vacuum is re-applied to the dust
separator.
9.3
Filter package
NOTE!
Fitting the steel ring correctly is important to maintain the tightness and durability
of the unit.
Filter replacement is to be noted in the service protocol of the unit. Replacing individual
filter bags is possible, but it is recommended that the whole filter package is replaced since
Summary of Contents for FlexPAK 800 DX
Page 2: ...FlexPAK 800 1000 DX 2...
Page 9: ...FlexPAK 800 1000 DX 7 A B C 4A 3 13 12 10 9 7 8 2 1 3 4 6 5 11...
Page 10: ...FlexPAK 800 1000 DX 8 4C 4B 11 7 8 9 12 13 16 15 14 17 18 19 20 21 10...
Page 11: ...FlexPAK 800 1000 DX 9 1 2 3 4 5 6 7 14 13 12 11 9 8 10 5 A B 6 7...
Page 14: ...FlexPAK 800 1000 DX 12 11 12 14 13...
Page 15: ...FlexPAK 800 1000 DX 13 1 0m 39 4 A B C 16 17 15 Min 2 1m 83 A A A A C...
Page 40: ...FlexPAK 800 1000 DX EN 38...
Page 64: ...FlexPAK 800 1000 DX CS 62...
Page 88: ...FlexPAK 800 1000 DX DA 86...
Page 160: ...FlexPAK 800 1000 DX FI 158...
Page 280: ...FlexPAK 800 1000 DX NO 278...
Page 306: ...FlexPAK 800 1000 DX PL 304...
Page 341: ...FlexPAK 800 1000 DX 339 RU FlexPAK 800 1000 DX FlexPAK 800 1000 DX 5 1 9 10...
Page 348: ...FlexPAK 800 1000 DX RU 346 7 7 1 1 2 3 Program 4 Set Parameter 5 6 7 8 9 10...
Page 351: ...FlexPAK 800 1000 DX 349 RU 2 X1 13 X1 14 3 3 10 DIR 12 SSR 12 DIR 10 8 4 DO3 24 9...
Page 356: ...FlexPAK 800 1000 DX RU 354...
Page 402: ...FlexPAK 800 1000 DX CN 400...
Page 403: ......
Page 404: ...www nederman com...