FlexPAK 800/1000
19
EN
3.3.14 Alarm! Dustbin Full
When a level indicator set for a time delay of 30 minutes is activated, then when the
delay has elapsed a message “Alarm! Dustbin Full” appears on the display and the unit is
stopped.
Empty the dust bin and press the green OK button
OK
to reset the Alarm.
ESC
OK
Alarm!
Dustbin Full
Max Time lapsed
Mo 09:50
Unit is Stopped
Reset OK ==>
3.3.15 Alarm! Main Filter Clogged
When the Delta pressure indicator is set, the MFDPS-Al timer starts to count down. When
the setting time has elapsed (T = 30.00 m), then the message, “Alarm Main Filter Clogged”
appears on the display and the Start/Stop button starts to flash. The unit is stopped. Fix the
problem with the clogged filter.
Press the green OK button
OK
to reset the Alarm.
ESC
OK
Alarm!
Main
Filter Clogged
Th 12:23
Unit is Stopped
Reset OK-->