3.6 Fuses
Table 3.2 Fuses
Fuse
Size
Type
Main fuse F1, 400 V
35 A
Slow mains fuses
Main fuse F1, 460 V
40 A
Slow mains fuses
Transformer, primary fuse F2 and F3
0,8 A
*
Slow fuses, 10,3×38
Transformer, secondary protection
PTC resistor
F4
50 mA
*
Fast, 5×20
F5
1 A
*
Slow, 5×20
* General size, see also included electrical diagrams.
3.7 Main components
WARNING! Explosion risk
• Never use the unit without an antistatic
plastic bag.
• Depending on the FlexPAK DX model used,
treat its explosion protection device carefully
so that it does not become damaged, see
CAUTION! Risk of equipment damage
Use Nederman original bags only.
and
show the main
components of the unit:
1 Collector bin, see
3 Textile filter bags, see
.
4 Filter holder, see
5 Filter Cleaning Valve (FCV), see
6 Connection duct from the dust extractor to the in-
.
7 Start and control unit, see
and
.
9 Emergency switch, see
10 Frequency converter, see
11 Frequency converter cooling air filter, see
and
.
and
.
13 High-pressure side channel fan, with pump char-
acteristic, see
14 PT100 sensor, see
.
15 Outlet silencer after fan, see
.
16 Control Filter and filter cartridge, see
.
18 Acoustic enclosure, see
.
19 Cooling air hose from the frequency converter
cabinet, see
20 Compressed air supply, see
21 Inlet, see
3.8 Connections
The exhaust air duct is to be routed straight
and as short a distance as possible.
The unit is CE-marked. Connections to the unit,
initial start-up and maintenance are to be car-
ried out according to the product manuals.
Equipment such as cables and hoses are not supplied
and are to be obtained locally.
shows the normal connections to the unit.
They are as follows:
1 The duct from workstations.
2 Isolation devise.
3 Pressure resistant duct between the unit and the
isolation device.
4 Exhaust air duct, Ø 160 mm (for lengths <12 m).
5 PS cable from valves at workstations.
6 Incoming 3-phase power supply with a Protective
Earth (PE) cable.
7 Compressed air supply, Ø 6 mm nylon hose.
8 Compressed air valve, size G1/4” or G1/2”.
9 Water and dirt-trap. The compressed air supply is
to be clean and dry.
10 Maintenance switch according to standard.
11 Power cable to the unit.
19
Summary of Contents for FlexPAK DX
Page 7: ...FlexPAK DX A E E A B C D G F 3A J I H 45 3B 7 ...
Page 8: ...FlexPAK DX 13 12 10 9 7 8 2 1 3 4 6 5 11 4A 11 7 8 9 12 13 15 14 17 16 10 18 4B 8 ...
Page 10: ...FlexPAK DX 6 A B 7 10 ...
Page 13: ...FlexPAK DX 11 12 13 14 13 ...
Page 14: ...FlexPAK DX A A A A C Min 2 1m 83 15 1 0 m 39 4 16 A B C 17 14 ...
Page 36: ...www nederman com ...