FlexPAK
EN
4
Loosen the screw for the lower sealing ring hold-
ing the filter top, see
, item A.
5
Lift of and put the filter top away.
6
Select one of two methods to remove the filter -
tilting the filter or using a lifting device - and con-
tinue with the steps accordingly.
7
Lifting device: Lift the filter straight up with a
crane or other lifting device, see
8
Tilt: Unscrew the eight screws for the protection
plate and remove it, see
.
9
Tilt: Unscrew the eight screws (four on each side)
attaching the filter to the frame legs according to
item A in
and item C in
NOTE!
If you cannot reach the four screws on the
other side, remove the side marked as item
B in
.
10 Tilt: Press the spring in the center with an appro-
priate tool according to item B, tilt the filter hori-
zontally and remove the filter, see
and
11 Insert the new filter and note the fitting of the
rubber sealing rings. See
. Items A–C,
shows how the rubber sealing rings are to be fit-
ted. When a used sealing ring is to be re-used, the
form when open may differ from the original form
as shown in item A. Use a screwdriver to bring the
edge of the module between the rubber lips to ob-
tain the result shown in item C.
NOTE!
Fitting the steel ring correctly is important
to maintain the tightness and durability of
the unit.
12 Assemble the unit in reversed order.
9.5 Check the filter cleaning function
WARNING! Risk of personal injury
Crush hazard. Pay attention when the com-
pressed air pressure cylinder and valve disc
move. Make sure that the protection hood over
the filter cleaning unit is fitted after the check.
Check the automatic filter cleaning as follows:
1
Check the automatic cleaning equipment once a
year.
2
Remove the top cover from the filter and inspect
the valve disc.
3
Start the unit and press the filter cleaning button,
see
. The compressed air cylinder should
lift the valve disc. Loud noise can be heard as air
rushes into the filter bin to blow off the dust from
the outside of the filter package. This will be re-
peated 3 times for each filter cleaning cycle.
4
Stop the vacuum unit and shut off the air supply.
5
Check the valve disc fastening, damage and wear.
Replace if required.
6
Replace the protecting top cover.
9.6 The motor and the fan unit
Inspect and clean the motor compartment regularly.
The motor has 2 ball bearings. The bearings are to be
replaced after approximately 15,000 hours of opera-
tion. If the ambient temperature often reaches 35°C
(95°F), the time between replacements is to be re-
duced. In any case, the bearings are to be replaced
every fifth year.
The bearings are a standard type. Contact Nederman
or an authorized Nederman distributor for replace-
ment of the bearings.
Old grease is to be removed and new grease used. The
grease is to meet the DIN 51825-K2N 40, SKF LGHP 2
or FAG Arcanol Multitop standards.
9.7 Cooling filter for the frequency con-
verter
The service life of the cooling filter for the frequency
converter depends on the air-bound dust surround-
ing the vacuum unit. The expected service life is 6–48
months. Check the filter regularly through the filter
holder grid. If the filter is clogged, the frequency con-
verter will shut off due to overheating.
Ensure that the cooling filter is not exposed to any
combustible materials. Running the unit without the
cooling filter may cause serious damage. When chan-
ging the filter, see the label placed over the filter in-
take.
The unit may never be run without a cooling filter for
the frequency converter.
9.8 Loading new software
NOTE!
• This section is only for Nederman qualified
service technicians. Only Nederman qualified
service technicians may make changes to, or
install new software.
• Make notes of actual parameter settings.
9.8.1 Frequency converter control panel
To change the software or install new software for
the unit, the parameters in the frequency converter
have to be changed by means of the frequency con-
verter control panel available from Nederman.
36
Summary of Contents for FlexPAK Standard
Page 9: ...FlexPAK 13 12 10 9 7 8 2 1 3 4 6 5 11 3 11 7 8 9 12 13 15 14 18 19 10 17 4 16 15 20 5 9...
Page 10: ...FlexPAK 6 1 2 3 6 7 8 9 16 15 14 13 11 10 12 4 5 7 10...
Page 12: ...FlexPAK 2 1 4 5 6 8 7 9 3 9 1 1643 1mm 65 662 1mm 26 2 1771 4 1mm 70 13mm 10 12...
Page 13: ...FlexPAK 11 12 13 14 13...
Page 14: ...FlexPAK 15 A B 16 14...
Page 15: ...FlexPAK A B C 4x 17 8x 18 15...
Page 16: ...FlexPAK A 4x B 19 Min 2 1m 83 20 1 0m 39 4 21 16...
Page 17: ...FlexPAK A B C 22 23 17...
Page 39: ...FlexPAK SUV Solenoid upper valve TVFD Twin valve feed out device EN 39...
Page 60: ...FlexPAK CS SUV Horn elektromagnetick ventil TVFD Za zen pro vypou t n dvojit ho ventilu 60...
Page 81: ...FlexPAK SUV verste magnetventil TVFD Udgangsenhed for tvillingeventil DA 81...
Page 127: ...FlexPAK SUV V lvula superior solenoide TVFD Dispositivo de vaciado por doble v lvula ES 127...
Page 148: ...FlexPAK FI SUV Solenoidin yl venttiili TVFD Kaksoisventtiilipoistolaite 148...
Page 171: ...FlexPAK SUV lectrovanne sup rieure TVFD Dispositif de vidage double vanne FR 171...
Page 194: ...FlexPAK HU SUV Fels m gneses szelep TVFD Ikerszelepes kiadagol berendez s 194...
Page 216: ...FlexPAK IT SUV Elettrovalvola superiore TVFD Dispositivo di svuotamento a doppia valvola 216...
Page 239: ...FlexPAK SUV Bovenste magneetklep TVFD Uitvoer van apparaat voorzien van dubbele klep NL 239...
Page 260: ...FlexPAK NO SUV vre magnetventil TVFD Utmatingsenhet med to ventiler 260...
Page 283: ...FlexPAK SUV G rny zaw r elektromagnetyczny TVFD Dwuzaworowe urz dzenie odprowadzaj ce PL 283...
Page 312: ...FlexPAK RU FlexPAK FlexPAK DX 5 1 9 8 5 2 5 5 2 1 6 1 3 Running 8 8 6 312...
Page 323: ...FlexPAK 9 1 9 2 N e d e r m a n 2 3 11 9 3 1 2 3 4 12 5 13 6 7 14 8 RU 323...
Page 326: ...FlexPAK RU N e d e r m a n 11 1 FlexPAK 93 6 326...
Page 328: ...FlexPAK RU SUV TVFD 328...
Page 364: ...FlexPAK ZH 9 3 Nederman CE 9 1 9 2 Nederman 2 3 11 9 3 1 2 3 4 12 5 13 6 7 14 8 364...
Page 368: ...FlexPAK ZH SUV TVFD 368...
Page 369: ...www nederman com...