FlexPAK
4 PLC settings
The following PLC displays show the different settings that can be configured for the unit.
4.1 Find a parameter and set its value
ESC
OK
Thu
10:45
2018-02-01
ESC
OK
Stop
>
Program
>
Setup
>
Network
>
Diagnos cs
>
Program
>
ESC
OK
Set Parameter
Program Name
Set Parameter
ESC
OK
FlexPak
Hi Vacuum Unit
OFF
Time To Service
2000 hours
ESC
OK
H-Meter
1/1
MI
=2000h:0m
OT
=0h:15m
MN
=1999h:45
MN Ext
=2000
ESC
OK
H-Meter
>
SSR_Time
>
Cool_Tmr
>
ClenCyl
>
FItClean
>
DIRTime
Z
Do the following to find a parameter and set its value:
1 From the PLC status screen, press the down arrow to go to the date and time screen.
2 Press Escape to go to the main menu.
3 Press the Down arrow to go to Program. Press OK to confirm.
4 Select Set Parameter. Press OK to confirm.
5 Use the Up or Down arrows to find the parameter. Press OK to confirm.
6 Use the Left and Right arrows to select a value.
7 Use the Up or Down arrows to set the value. Press OK to confirm.
8 Press Escape to go to the main menu.
9 Press Escape to go to the date and time screen.
10 Press the Up arrow to exit.
There are several other input menus on the same level as the date and time screen. If pressing the Down
arrow takes the PLC to one of those menus. Use the Left arrow to get to the date and time screen.
The blinking cursor shows the current value that can be changed.
26
Summary of Contents for FlexPAK
Page 7: ...FlexPAK 2 7 ...
Page 54: ...FlexPAK PLC setting Default value Customer specific value 54 ...
Page 55: ...www nederman com ...