HD100
13
QMM033(02)
EN
9
Using the centrifuge
9.1
Before start-up
WARNING:
Before any kind of activity, the SAFETY REGULATIONS
(Chapter 4) must be read carefully, and the safety regulations must be strictly
adhered to.
The centrifuge is designed for approximately 1-5 cm long chips. Before feeding
the centrifuge solid parts should be separated to reduce wear and sound level.
Study Fig.
1
-
Material flow in centrifuge
- where a general description is
provided.
Check the following points prior to putting into operation:
1.
Free rotation.
The drum should be able to be turned round by hand.
2.
Motor loading.
Check zero-load power and compare with power during loading and
rating data of motor.
3.
Observation of zero-load sound.
Attention should be paid to the normal sound level of the equipment.
NOTE!
A screaming noise may be emitted by the V-belt when the drum
is accelerating. This is normal.
4.
Always start machine unloaded.
If the machine is started when loaded then start load will exceed motor
capacity. The centrifuge must not be fed until the correct speed of the
drum has arised.
5.
Feed the centrifuge evenly.
Since the centrifuge works continuously it is of great importance that
it is fed evenly to ensure a level of residual moisture in the centrifuged
chips as low as possible. The feeding of the centrifuge should be done in
intervals by a conveyor. As default setting on the feeding conveyor 4 s
stop time is used followed by 2 s run time. This value can vary depending
on the shape of the material.
6.
Supplementary adjustment.
NEDERMAN Swarf Centrifuge is on delivery adjusted to cope with the
majority of chip types unless otherwise specified. If a chip type should be
run subsequently to installation which was unknown to us on the occasion
of installation then a supplementary adjustment may be made.
The operator should always be aware of the normal power consumption of
the motor, normal outflow of solid particles, the liquid content of the material
and the level of vibration. By considering the above mentioned factors and
observing modifications one can be quite sure that the centrifuge will function
properly.
9.2
Operation
Figure 1 shows the material flow through the centrifuge.
The material fed in through the top inlet hopper (1), glides down and is fed
directly to the drum walls (6). On contact with the drum walls the material is
accelerated to the speed of the drum at the periphery. During this acceleration
Summary of Contents for HD100