Preface

This manual is for the correct installation, use and maintenance of this product. 

Read it carefully before using this product or carrying out maintenance. 

Replace the manual immediately if lost.
This product has been designed to meet the requirements of relevant EC 

directives. To maintain this status, all installation, repair and maintenance 

work for this product is to be carried out by qualified personnel using only 

original spare parts. Contact the nearest authorized distributor or Nederman 

for advice on technical service and obtaining spare parts. Also read Chapter 

‘4 Safety’ thoroughly.

Nederman continuously improves its products design and efficiency through 

modifications, and reserves the right to do so without introducing these 

improvements to previously supplied products. Nederman also reserve the right 

to, without previous notice, modify data and equipment as well as operating 

and maintenance instructions.

2.1 

Foreword

Your 

HD100

 Swarf Centrifuge has been manufactured by:

Nederman Manufacturing Poland Sp. z o. o.

ul. Okólna 45 А

05-270 Marki, Poland
Tel:   

+48 22 7616000

Fax:   

+48 22 7616099

E-mail: info@nederman.pl

www.nederman.com.pl 

www.nederman.com

NEDERMAN Swarf Centrifuges guarantee good design, quality components 

and skilled labour plus years of experience in swarf handling and swarf 

crushing. All these abilities have been used to design a product with high 

reliability and long service life. We are convinced that your experiences will 

confirm your choice of NEDERMAN Swarf Centrifuge. 

Length of life and reliability can, as with any machine tool, be prolonged with 

correct installation and correct maintenance. It pays off to follow our advice for 

maintenance.
This maintenance manual consists of instructions and spare parts list for your 

new NEDERMAN Swarf Centrifuge. It also contains greasing instructions, 

exploded view and a simple schedule for trouble-shooting.
NEDERMAN Swarf Centrifuges are normally used in swarf handling systems 

which we design, sell and install. 
All Swarf Centrifuges which leave our works are checked and do not need any 

additional maintenance other than stated in this manual. 

For orders of spare parts and if you want to contact our engineers please find 

our phone number and address at the front page of this instruction.

Summary of Contents for HD100

Page 1: ...ISNING NO FELHASZNÁLÓI KÉZIKÖNYV HU HANDLEIDING NL İŞLETME KILAVUZU TR INSTRUKCJA UŻYTKOWANIA PL KASUTUSJUHEND ET KÄYTTÖOHJEET FI LIETOŠANAS INSTRUKCIJA LT MANUAL DE INSTRUCCIONES ES MANUAL DE INSTRUÇÕES PT MANUAL DE UTILIZARE RO MANUALE D ISTRUZIONE IT MANUEL D INSTRUCTION FR NAUDOJIMO INSTRUKCIJA LV NAVODILA ZA UPORABO SL NÁVOD K OBSLUZE CS NÁVOD NA POUŽITIE SK ΕΓΧΕΙΡΙΔΙΟ ΧΡΗΣΗΣ EL НАРЪЧНИК С ИН...

Page 2: ...TL2M 2 QMM033 02 HD100 ...

Page 3: ...TL2M 3 QMM033 02 HD100 Figures 4 English 7 ...

Page 4: ...HD100 4 QMM033 02 Figures 1 2 ...

Page 5: ...HD100 5 QMM033 02 3 ...

Page 6: ...HD100 6 QMM033 02 4 ...

Page 7: ...cal data 11 6 Main components 11 6 1 Accessories 11 7 Before installation 11 7 1 Delivery checks 11 7 2 Installation requirements 11 8 Installation 12 8 1 Installing the centrifuge 12 9 Using the centrifuge 13 9 1 Before start up 13 9 2 Operation 13 10 Maintenance 14 10 1 Maintenance instruction 14 10 2 Lubrication 14 10 3 Spare parts 15 11 Recycling 16 12 Troubleshooting 16 13 Acronyms and abbrev...

Page 8: ...ording to the manual Proper technical documentation for the above mentioned machine has been prepared according to Annex VII part B Technical Dpt Manager at Nederman Manufacturing Poland Sp z o o is responsible for this documentation The product is also in conformity with other following directives Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC and complies wi...

Page 9: ...d Sp z o o ul Okólna 45 А 05 270 Marki Poland Tel 48 22 7616000 Fax 48 22 7616099 E mail info nederman pl www nederman com pl www nederman com NEDERMAN Swarf Centrifuges guarantee good design quality components and skilled labour plus years of experience in swarf handling and swarf crushing All these abilities have been used to design a product with high reliability and long service life We are co...

Page 10: ...d personnel only At connection of voltage feed as well as at service and maintenance work on the hydrostatic clarifier the circuit breaker must be off Test the emergency stop at installation and always when maintenance and service have been done The centrifuge must not be operated with the covers removed Materials able to centrifuge are different qualities of steel swarf as well as brass and cast ...

Page 11: ...nents see Fig 1 Table 6 1 Main components of Swarf Centrifuge HD100 Item N Component name 1 Inlet wet chips 2 Access door 3 Self cleaning wedge bar screen 4 Outlet dry chips 5 Separator bowl 6 Accelerator zone 7 Outlet liquid 6 1 Accessories The screen opening is delivered as a standard 0 7 mm if not otherwise specified in the order Other screen openings may be fitted The centrifuge is equipped wi...

Page 12: ... Despite the fact that the parts are individually balanced a certain imbalance may arise when material is fed in To avoid vibrations being transferred to mountings the centrifuge is installed on vibration absorbers NEDERMAN Swarf Centrifuge is delivered fully fitted Observe care during installation and always use the lifting hooks which it is equipped with The mountings should be level and suffici...

Page 13: ... the centrifuge works continuously it is of great importance that it is fed evenly to ensure a level of residual moisture in the centrifuged chips as low as possible The feeding of the centrifuge should be done in intervals by a conveyor As default setting on the feeding conveyor 4 s stop time is used followed by 2 s run time This value can vary depending on the shape of the material 6 Supplementa...

Page 14: ...ked and maintained Daily checks should be made at the start of operations until a permanent maintenance schedule can be established When this has been done only routine checks and general observations are necessary All parts coming into contact with the material which passes through the centrifuge are subject to wear Negligent or delayed replacement of worn parts results in high repair costs and u...

Page 15: ...ave for drum pce 5 901702 Shaft plate pce 6 901614 Bearing cover front pce 7 901612 Bushing front bearing pce 8 901708 Bearing house cover pce 9 76374736 Shaft pce 10 901613 Bushing rear bearing pce 11 9702407 Belt pulley pce 9702513 Bushing pce 12 901706 Bearing cover rear pce 13 971523 Lubricating pump pce 14 76374737 Vibration absorber 4 pcs set 15 76374738 V belt 3 pcs set 16 901701 Housing pc...

Page 16: ...ect maintenance is the best insurance against the development of defects Table 12 1 Trouble shooting guide Problem Possible cause Solution Motor starts but drum stands still Belts off Replace belts Motor protector fuses or motor sluggish high power consumption Blown fuse Check replace fuse Motor fault Replace motor Excess feed Check that feed is not higher than indicated in order document Solid pa...

Page 17: ...HD100 17 QMM033 02 EN Nederman Manufacturing Poland Sp z o o ul Okólna 45А 05 270 Marki Poland Tel 48 22 7616000 Fax 48 22 7616099 E mail info nederman pl www nederman com pl ...

Page 18: ...HD100 EN 18 QMM033 02 EN ...

Reviews: