L-PAK 150/250 Advanced
NOTE!
There are several other input menus on the same level as the date and time screen. If pressing the down
arrow takes the PLC to one of those menus, use the left arrow to get to the date and time screen.
Daily AM setting
ESC
OK
WeekTmr
1/2
D1
= MTWTF
On1
= 00:00
Off1
= -- --
D2
= MTWTF
On2
= -- --
D1: = MTWTF: Default setting; Monday, Tuesday, Wednesday, Thursday and
Friday.
On1 = Time the unit is set to ‘Standby’ at chosen D1 days. Default setting is
no preset time.
Off1 = The time the unit is set to ‘Off’ on chosen D1 days. Default setting is
no preset time.
Daily PM setting
ESC
OK
WeekTmr
1/2
D1
= MTWTF
On1
= 00:00
Off1
= -- --
D2
= MTWTF
On2
= -- --
D2 = MTWTF: Default setting; Monday, Tuesday, Wednesday, Thursday and
Friday.
On2 = Time the unit is set to ‘Standby’ at chosen D2 days. Default setting is
no preset time.
Off2 = The time the unit is set to ‘Off’ on chosen D2 days. Default setting is
no preset time.
Weekend or second shift setting
ESC
OK
WeekTmr
2/2
Off2
= -- --
D3
= - - - - -SS
On3
= -- --
Off3
= -- --
Pulse
= Off
D3 = _ _ _ _ _ SS: Default setting; Saturday and Sunday.
On3 = _ _: Default setting Time the unit set to ‘Stand By’ on chosen D3 days.
Default setting is no preset time.
Off3 = The time the unit is set to ‘Off’ on chosen D3 days. Default setting is
no preset time.
Example
D3=_ _ _ _ _ SS
Saturday, Sunday
On3 = 09:00
Unit starts at 9:00 in the morning
Saturday, Sunday
Off3 = 13:00
Unit stops at 13:00 in the after-
noon
Saturday, Sunday
NOTE!
Pulse = Off: The pulse parameter must always be set to Off.
NOTE!
When the timer stops the unit and a valve at a workstation is in its open position, the unit will start imme-
diately once the timer puts the unit in standby mode.
It is not necessary to use the timer function. The function can be switched off by setting the display to show
only dashes. However, it is recommended that the timer function is used, as this ensures that the unit is
switched off even when a valve remains open, for example, overnight.
NOTE!
If the weekly timer has been activated, the amount of time the unit can be used during the day before it
automatically goes into Off mode can be extended if the optional external standby button accessory is
used, see