L-PAK 150/250 Advanced
6.2.7 OTTmr
Menu for setting the overtime timer. If the unit needs to be used after the weekly timer has expired, the unit
can be turned on for a set number of hours by pressing the external standby button. When the OTTmr expires,
the machine goes back into Off mode.
If the unit is in Off mode and the weekly timer is not used, quickly pressing the external standby button (less
than 2 seconds) puts the unit into Standby mode for the time set in ‘T’, for example, two hours. See the figure
below.
If the unit is in Standby mode and the weekly timer is not used, quickly pressing the external standby button
(less than 2 seconds) puts the unit into Off mode after the time set in ‘T’, for example, two hours. See the figure
below.
If the weekly timer is being used, quickly pressing the external standby button (less than 2 seconds) keeps
the unit into Standby mode for an additional two hours after the closing time set in the weekly timer, see
.
To reset OTTmr so that the time is not extended, press the external standby button longer than 2 seconds and
then release.
ESC
OK
OTTmr
1/1
T
= 02:00h
Ta = 00:00
T = 02:00h: Extra time before the unit goes into Off mode. The default set-
ting is 2 hours.
Ta = 00:00: The elapsed time since the overtime timer started.
6.2.8 PSIFC-I2
Standard Pilot Signal input Terminal 13-14 is now configurable.
When the input is activated, the unit starts as usual but depends on the setting below for filter cleaning. Filter
cleaning can be done during the running mode.
Standard input
Switch = Off: It is possible to activate filter cleaning any time when the motor is running by either timer or by
manual cleaning.
PSIFC input
Switch = On: Cleaning process cannot be activated by the timer or by manual cleaning. Cleaning starts after PS =
off.
ESC
OK
PSIFC-I2
1/1
Switch = Off
Switch = Off: Default setting.
6.2.9 FCTmr
Menu for activating and setting time between timer-controlled filter cleaning.
ESC
OK
FCTmr
1/1
Stat
= ON
TH
= 01:00s
TL
= 60:00m
Stat =On Filter Cleaning timer activated Default is On.
TH=01:00s: Do not change the default setting of 1 second.
TL=60:00m: Time between automatic filter cleanings. The default setting
is 60 minutes.
Ta=00:00: The elapsed time since the last automatic cleaning was activ-
ated.