L-PAK 150/250 Standard

7

EN

4.2 

Unit operation modes

L-PAK 150/250 Advanced has the following four operation modes:

1. 

Off mode

2. 

Standby mode

3. 

Running mode

4. 

Idling mode

See Section 

5.1. Status messages

 for more information about each mode. How the unit 

moves from one operation mode to another is explained below. See also Figure 1 for a flow 

chart showing how the unit goes through its four different operation modes.
When the unit is in Off mode, the unit can be put into Standby mode (the unit is ready) 

with its motor off and the Filter Cleaning Valve (FCV) closed by pressing the Standby/

Running button. While the unit is in Standby mode, the unit can be put back into Off mode 

again by pressing the Standby/Running button.
The unit goes from Standby mode into Running mode when it receives a pilot signal by a 

valve being opened at one or more work stations (in other words, someone starts to work). 

The unit’s motor is now on and the FCV is closed. The DIR_Time and SSR_Time timers are 

not started, see Sections 

6.2.4. DIR_Time

 and 

6.2.3. SSR_Time

.

The unit stays in Running mode as long as there is an active pilot signal. However, the unit 

can still be put into Off mode by pressing the Standby/ Running button.
Note that if only one workstation is connected to the unit, or if only one work station is 

in use and work stops at that one station, the pilot signal stops. If there is more than one 

work station connected to the unit, and more than one work station is in use, the pilot 

signal only stops if work stops at all workstations (in other words, all valves close).
When the pilot signal stops, the DIR and SSR timers start. If work resumes at one or more 

work stations within 10 seconds, the unit stays in Running mode. The DIR and SSR timers 

are reset back to zero and are stopped.
If DIR_Time is set for 10 seconds (default), and the pause in work is longer than 10 seconds, 

DIR_Time elapses. The unit then goes into Idling mode with its motor on and the FCV open.
If a new pilot signal is sent within 12 minutes, the unit goes back into Running mode. The 

DIR and SSR timers are again reset to zero and are stopped. However, if SSR_Time is set for 

12 minutes, which is the default setting, and there is no new pilot signal within 12 minutes, 

SSR_Time also elapses.
The unit then goes into Standby mode until it either receives a new pilot signal that puts 

the unit back into Running mode, or the unit is turned off (in other words, put into Off 

mode) by pressing the Standby/Running button.

PLC messages

The following sections show the different status, warning and alarm messages that can be 

seen in the PLC display.

5.1 

Status messages

The following status messages give information about what mode the unit is in or what 

routine service is being performed.

Summary of Contents for L-PAK Series

Page 1: ...L PAK Series L PAK 150 250 Standard 50Hz 60Hz 2130224 00 2018 09 13 Original PLC manual EN PLC MANUAL PLC Manual...

Page 2: ......

Page 3: ...L PAK 150 250 Standard 3 Figures 4 English 5...

Page 4: ...m ESC OK Hi Vacuum Unit Running Time 05 33 Min DIRTm 00 00 s OTTmr 00 00 h ESC OK Hi Vacuum Unit IDLING Time To StandBy T 05 33m PS PS ESC OK Hi Vacuum Unit Running Time 05 33 Min DIRTm 10 00 s OTTmr...

Page 5: ...1 5 Filter Cleaning 9 5 1 6 Status report 9 5 2 Warning messages 9 5 2 1 Time for service 10 5 2 2 Warning Fan Hi Temp 10 5 3 Alarm messages 10 5 3 1 Alarm Fan Hi Temp 11 5 3 2 Alarm Motor Protector...

Page 6: ...ocal Nederman representative immediately 2 Safety This document contains important information that is presented as either a warning caution or note See the following examples WARNING Risk of personal...

Page 7: ...f only one work station is in use and work stops at that one station the pilot signal stops If there is more than one work station connected to the unit and more than one work station is in use the pi...

Page 8: ...r Pilot Signal Mo 15 33 2018 01 22 5 1 3 Running Running mode The unit in Running mode The pump motor is on and the unit generates a vacuum The FCV is closed ESC OK Hi Vacuum Unit Running Time 05 33 M...

Page 9: ...en appears 1 Press Escape ESC and the up arrow at the same time to show the Status Report screen 2 Press Escape ESC and the up arrow at the same time to show the next Status Report screen Sn Software...

Page 10: ...vates a timer start which is shown in the display if the fan does not cool down when the timer elapses the vacuum unit will stop and the Alarm message Alarm Fan Hi Temp is activated ESC OK Warning Fan...

Page 11: ...Alarm Fan Hi Temp Vacuum Unit O Th 11 23 Reset OK Th The actual day and time when L Pak was stopped 5 3 2 Alarm Motor Protector Activated The motor is overheated Correct the problem and press OK OK to...

Page 12: ...3 Press the down arrow to go to Program Press OK OK to confirm 4 Select Set Parameter Press OK OK to confirm 5 Use the up or down arrows to find the parameter Press OK OK to confirm 6 Use the left and...

Page 13: ...confirm 5 Press the down arrow to go to Set Clock Press OK OK to confirm 6 Use the left and right arrows to move to cursor to parameter value Press OK OK to confirm 7 Use the up or down arrows to set...

Page 14: ...filter cleaning ESC OK FCTmr 1 1 Stat ON TH 01 00s TL 60 00m Stat On Filter Cleaning timer activated Default is On TH 01 00s Do not change the default setting of 1 second TL 60 00m Time between automa...

Page 15: ...4 Warning Alarm output Q4 Potential free output Terminal X1 33 34 When an alarm is activated Output Q4 and White lamp button on the control box side flash with interval 1 second on 1 second off Warnin...

Page 16: ......

Page 17: ...www nederman com...

Reviews: