WARNING! Risk of personal injury

Always disconnect the fan motor from mains with the isolator before starting any

main-tenance or repair work.

Always use a breathing mask when repairing and servicing the system.

WARNING! 

Risk of personal injuries.

Always use a respirator when repairing and servicing the system

Installation, repair and maintenance work is to be carried out by qualified personnel 

using  only  original  Nederman  spare  parts.  Contact  your  nearest  authorized 

distributor or Nederman for advice on technical service.

NOTE! 

S

ervice intervals are based on the unit being professionally

 

maintained. 

Maintenance is recommended at least once a year.

Listen for noise and touch the fan casings with the hand and notice if the fan
vibrates in an abnormal way. If necessary, disconnect the fan from 

power

,

dismount the

 

fan and clean the impeller (not possible on N29 fan).

(wear

 a 

respirator)

Check the fan’s suction capacity. On 3-phase fans, check that the motor shaft
rotates in the right direction. Check that the ducts are not blocked. Clean if
necessary

 

(

wear

 a 

respirator

).

Check the electrical ins

tallation.

Check that the 

power

 cable is not worn or damaged.

If the fan has been mounted on a wall or in the ceiling, check the fittings.

Check and tighten any loose duct connections.

Check that the guard nets are in position.

6.1  Spare Parts

Recycling

The product has been designed for component materials to be recycled. Different 

material types must be handled according to relevant local regulations. Contact the 

distributor or Nederman if uncertainties arise when scrapping the product at the end of 

its service life.

 Nederman Customer Service & Technical Support        

techsupport.us@nederman.com

        +1 (336) 821-0800 

13

 

CAUTION! Risk of equipment damage
Use only Nederman original spare parts and accessories.

Contact your nearest authorized distributor or Nederman for advice on technical service 
or if you require help with spare parts. See also www.nederman.com.

   

 

Ordering Spare Part

s

When ordering spare parts always state the following:

• The part number and control number (see the product identification plate).

• Detail number and name of the spare part

            (see www.nederman.com/en/service/spare-part-search).

• Quantity of the parts required.

Summary of Contents for N Series

Page 1: ...REV 1 0523 N16 N24 N27 N40 N29 Installation Operation Manual Fans Pumps N Series Fans 16 24 27 29 40...

Page 2: ...trical installation 12 5 Use N16 24 27 29 40 12 5 1 Starting Instructions 12 5 2 Outdoor Use Draining 12 6 Maintenance 13 6 1 Spare Parts 13 7 Recycling 13 Figures 4 Table of Contents Nederman Custome...

Page 3: ...sions of the following directives and standards Directives 2006 42 EC 2014 30 EU 2011 65 EU Standards EN 60204 1 The name and signature at the end of this document is the person responsible for both t...

Page 4: ...93 mm c c 9 06 230 mm M8 x4 N24 N27 13 4 340 mm N16 12 6 320 mm 18 457 mm 7 3 185 mm c c 9 06 230mm 6 3 160 mm 18 8 478 mm M8 x4 Figures 1 1 3 3 6 3 160 mm 10 8 275 mm 18 7 475 mm 5 5 140 mm 25 635 mm...

Page 5: ...N16 24 27 29 40 RR min 2 75 ft 0 85 m 5 IP 68 6 6 7 7 R 3x 0 2 5 mm 8 8 Rotation direction N40 Recommended protection class 5...

Page 6: ...N16 24 27 29 40 N16 1 PH m h Pa N16 3 PH m h Pa 9 6...

Page 7: ...N16 24 27 29 40 N24 1 PH m h Pa N24 3 PH m h Pa 10 7...

Page 8: ...N16 24 27 29 40 N27 1 PH m h Pa C D E F N27 3 PH m h Pa 11 8...

Page 9: ...N16 24 27 29 40 N29 3 PH m h Pa E F G H N40 3 PH m h Pa 12 9...

Page 10: ...at is presented as a warning caution or note as follows WARNING RiskofPersonalInjury Warnings indicate a potential hazard to the health and safety to personnel and how to avoid that hazard CAUTION Ris...

Page 11: ...RNING Riskofpersonalinjuries Guard nets must be mounted on the inlet and outlet of the fan unless the fan is fixed and or directly connected to ducting system See Figure 4 page 4 WARNING Riskofpersona...

Page 12: ...he fan must not be used without ductwork connected unless the inlet and outlet are equipped with approved guard nets Ear protectors is to be worn when working near the fan Check the cable connections...

Page 13: ...heck that the ducts are not blocked Clean if necessary wear a respirator Check the electrical installation Check that the power cable is not worn or damaged If the fan has been mounted on a wall or in...

Page 14: ...orrect tools and knowledge to solve any machinery issues and improve its performance Be sure to ask if your technician is certified by Nederman Our services for extraction and filtratio n systems are...

Reviews: