background image

en 

Installation instructions

10

12  Installation instructions

Observe this information when installing the appliance.

12.1 Included with the appliance

After unpacking all parts, check for any damage in
transit and completeness of the delivery.

Depending on the appliance specifications

12.2 Safety clearances

Comply with the safety clearances for the appliance.

For Australia and New Zealand the minimum safety
clearance above electrical cooktops must be 600 mm.

 12.3 Secure installation

Follow these safety instructions when in-
stalling the appliance.

WARNING ‒ Risk of poisoning!

Risk of poisoning from flue gases being
drawn back in. Room-air-dependent heat-pro-
ducing appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the
room in which they are installed and dis-
charge the exhaust gases into the open
through an exhaust gas system (e.g. a chim-
ney). With the extractor hood switched on, air
is extracted from the kitchen and the adjacent
rooms. Without an adequate supply of air, the
air pressure falls below atmospheric pressure.
Toxic gases from the flue or the extraction
shaft are sucked back into the living space. 

Always ensure adequate fresh air in the
room if the appliance is being operated in
exhaust air mode at the same time as a
room-air-dependent heat-producing appli-
ance is being operated.

It is only possible to safely operate the ap-
pliance if the pressure in the room in which
the heating appliance is installed does not
drop more than 4 Pa (0.04 mbar) below at-
mospheric pressure. This can be achieved
whenever the air needed for combustion is
able to enter through openings that cannot
be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or by
other technical means. An incoming/ex-
haust air wall box alone does not ensure
compliance with the limit.

In any case, consult your responsible chim-
ney sweep. They are able to assess the
house's entire ventilation setup and will
suggest the suitable ventilation measures
to you.

Unrestricted operation is possible if the ap-
pliance is operated exclusively in circulat-
ing-air mode.

Summary of Contents for D46BR Series

Page 1: ...Extractor hood en User manual and installation in structions D46BR D49ED D46ED...

Page 2: ...ildren must not perform cleaning or user maintenance unless they are at least 15 years old and are being supervised Keep children under the age of 8 years away from the appliance and power cable 1 4 S...

Page 3: ...t A ventilation appliance installed above the cooker may be come damaged or catch fire Only operate the gas hobs with cookware on them Select the highest fan setting Never operate two gas hobs simulta...

Page 4: ...trols with stainless steel cleaners Condensation that flows back in may damage the ap pliance The air extraction duct must be installed with a gradient of at least 1 from the appliance If you put inco...

Page 5: ...eyed into a non functioning smoke or ex haust gas flue you must obtain the consent of the heating engineer re sponsible If the exhaust air is conveyed through the external wall a tele scopic duct shou...

Page 6: ...Press or Switching on the lighting The lighting can be switched on and off independently of the ventilation system Press Switching off the lighting Press 6 2 Control panel variant 3 Switching on the a...

Page 7: ...hock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse box Do not use steam or high pressure cleaners to clean the appliance...

Page 8: ...ng the grease filter Page 7 1 Observe the information regarding the cleaning agents Cleaning products Page 7 2 Soak the grease filter in hot soapy water Use special grease solvent for stubborn dirt Yo...

Page 9: ...tails and the Cus tomer Service telephone number to find them again quickly 10 Accessories You can buy accessories from the after sales service from specialist retailers or online Only use original ac...

Page 10: ...tracted from the kitchen and the adjacent rooms Without an adequate supply of air the air pressure falls below atmospheric pressure Toxic gases from the flue or the extraction shaft are sucked back in...

Page 11: ...ges Wear protective gloves The appliance may fall down if it has not been properly fastened in place All fastening components must be fixed firmly and securely in place Changes to the electrical or me...

Page 12: ...appliance s power supply circuit Sharp edged components inside the appliance may damage the connecting cable Do not kink or trap the connecting cable The connection data can be found on the rating pla...

Page 13: ...unit 2 Use the screws provided to secure the handle strip to the filter pull out 3 Connect the enclosed power cord to the appliance and secure the stain relief 4 Screw the two angle brackets to the a...

Page 14: ...iate floor must not rest on the housing The front panel must not be secured to the housing Access to the housing must remain possible in or der to change the filter and for after sales service Changin...

Page 15: ......

Page 16: ...Stra e 34 81739 M nchen GERMANY 9001530132 9001530132 021201 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton K...

Reviews: