background image

Safety

 en

3

WARNING ‒ Risk of poisoning!

Risk of poisoning from flue gases being
drawn back in. Room-air-dependent heat-pro-
ducing appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the
room in which they are installed and dis-
charge the exhaust gases into the open
through an exhaust gas system (e.g. a chim-
ney). With the extractor hood switched on, air
is extracted from the kitchen and the adjacent
rooms. Without an adequate supply of air, the
air pressure falls below atmospheric pressure.
Toxic gases from the flue or the extraction
shaft are sucked back into the living space. 

Always ensure adequate fresh air in the
room if the appliance is being operated in
exhaust air mode at the same time as a
room-air-dependent heat-producing appli-
ance is being operated.

It is only possible to safely operate the ap-
pliance if the pressure in the room in which
the heating appliance is installed does not
drop more than 4 Pa (0.04 mbar) below at-
mospheric pressure. This can be achieved
whenever the air needed for combustion is
able to enter through openings that cannot
be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or by
other technical means. An incoming/ex-
haust air wall box alone does not ensure
compliance with the limit.

In any case, consult your responsible chim-
ney sweep. They are able to assess the
house's entire ventilation setup and will
suggest the suitable ventilation measures
to you.

Unrestricted operation is possible if the ap-
pliance is operated exclusively in circulat-
ing-air mode.

WARNING ‒ Risk of fire!

Fatty deposits in the grease filters may catch
fire.

Never operate the appliance without a
grease filter.

Clean the grease filters regularly.

Never work with naked flames close to the
appliance (e.g. flambéing).

Do not install the appliance near a solid
fuel heating appliance (e.g. wood- or coal-
burning) unless the heating appliance has
a sealed, non-removable cover. There must
be no flying sparks.

Hot oil or grease ignites very quickly.

Always supervise hot oil and fat.

Never extinguish burning oil or fat with wa-
ter. Switch off the cooking zone. Extinguish
flames carefully using a lid, fire blanket or
something similar.

When gas burners are in operation without
any cookware placed on them, they can build
up a lot of heat. A ventilation appliance in-
stalled above the cooker may become dam-
aged or catch fire.

Only operate the gas burners with cook-
ware on them.

Operating multiple gas hobs at the same time
generates a great deal of heat. A ventilation
appliance installed above the cooker may be-
come damaged or catch fire.

Only operate the gas hobs with cookware
on them.

Select the highest fan setting.

Never operate two gas hobs simultan-
eously on the highest flame for longer than
15 minutes. Two gas hobs correspond to
one large burner.

Never operate large burners of more than
5  kW with the highest flame for longer
than 15 minutes, e.g. a wok.

WARNING ‒ Risk of burns!

The accessible parts of the appliance become
hot during operation.

Never touch these hot parts.

Keep children at a safe distance.

The appliance becomes hot during operation.

Allow the appliance to cool down before
cleaning.

Summary of Contents for D65IHM1S0

Page 1: ...Extractor hood en User manual and installation instructions D65IHM1S0B D65IHM1S0 D95IHM1S0B D95IHM1S0 ...

Page 2: ...on location Only use this appliance For extracting cooking vapour In private households and in enclosed spaces in a domestic environment Up to an altitude of max 2000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group This appliance may be used by children aged 8 or over and by people who have reduced physical sensory or mental abilities or inad equate ...

Page 3: ...cted operation is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance without a grease filter Clean the grease filters regularly Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a solid fuel heating appliance e g wood or coa...

Page 4: ...taff Only use genuine spare parts when repair ing the appliance If the power cord of this appliance is dam aged it must be replaced by trained spe cialist staff An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse box Do not use steam or high pressure clean ers to clean the appliance WARNING Risk of explosion Highly caustic a...

Page 5: ... require it The lighting does not consume any energy Clean or replace the filters at regular intervals The effectiveness of the appliance is increased Put the cooking lid on The cooking vapours and condensation are re duced 4 Operating modes You can use your appliance in air extraction mode or circulating air mode 4 1 Air extraction mode The air which is drawn in is cleaned by the grease fil ters ...

Page 6: ...intermediate position can be used to eliminate particularly strong cooking smells and large amounts of steam Take hold of the filter cover in the centre and open it carefully 7 Cleaning and servicing To keep your appliance working efficiently for a long time it is important to clean and maintain it carefully 7 1 Cleaning products You can obtain suitable cleaning products from after sales service o...

Page 7: ...online shop 7 3 Cleaning controls WARNING Risk of electric shock Penetrating moisture may cause an electric shock Do not use wet sponge cloths 1 Observe the information regarding the cleaning agents Cleaning products Page 6 2 Clean using a damp sponge cloth and hot soapy water 3 Dry with a soft cloth 7 4 Removing the grease filter WARNING Risk of injury Risk of injury when opening and closing the ...

Page 8: ...been inserted incorrectly carefully push the lock forwards remove the grease filter and insert it correctly 8 Troubleshooting You can rectify minor faults on your appliance yourself Read the troubleshooting information before contacting after sales service This will avoid unnecessary costs WARNING Risk of injury Improper repairs are dangerous Repairs to the appliance should only be carried out by ...

Page 9: ...d the production number FD of your appliance The contact details for Customer Service can be found in the enclosed Customer Service directory or on our website 10 1 Product number E Nr and production number FD You can find the product number E Nr and the pro duction number FD on the appliance s rating plate Depending on the model the rating plate can be found Inside the appliance remove grease fil...

Page 10: ...rehensive range of products for your appliance in our brochures and online www neff international com Accessories vary from one appliance to another When purchasing accessories always quote the exact product number E no of your appliance You can find out which accessories are available for your appliance in our online shop or from our after sales service 12 Installation instructions Observe this i...

Page 11: ...an adequate supply of air the air pressure falls below atmospheric pressure Toxic gases from the flue or the extraction shaft are sucked back into the living space Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as a room air dependent heat producing appli ance is being operated It is only possible to safely operate the ap plianc...

Page 12: ...ll The distance between the appliance and wall or high sided unit must be at least 50 mm Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non remov able cover is available There must be no flying sparks WARNING Risk of inj...

Page 13: ...as been correctly installed The mains plug for the mains power cable must be easily accessible after the appliance is installed If this is not possible an all pole isolating switch must be integrated into the permanent electrical in stallation according to the conditions of overvoltage category III and according to the installation regula tions The permanent electrical installation must only be wi...

Page 14: ...s and the weight of the appliance 5 Check the cut out area for existing cables of other appliances Preparing the wall 1 Observe the information on the installation situation Page 13 2 Ensure that there are no electrical wires gas pipes or water pipes in the area where holes are to be drilled 3 Cover the hob to prevent damage 4 Determine the position of the extractor hood and lightly mark where the...

Page 15: ...air pipe connector 2 Establish the connection to the exhaust air opening 3 Seal the joints Establishing the exhaust air connection exhaust pipe 120 mm diameter 1 Secure the reducing connector to the air pipe con nector 2 Secure the exhaust pipe to the air pipe connector 3 Establish the connection to the exhaust air opening 4 Seal the joints Fitting the flue duct WARNING Risk of injury Components i...

Page 16: ...l Wery Straße 34 81739 München GERMANY 9001641000 9001641000 010907 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton Keynes MK12 5PT United Kingdom ...