en
30
Eliminating minor faults yourself
Before you call customer service:
Please check whether you can eliminate the fault yourself based on the following
information.
Customer service will charge you for advice – even if the appliance is still under
guarantee!
Fault
Possible cause
Remedial action
Temperature differs
greatly from the set
value.
In some cases it is adequate
to switch off the appliance
for 5 minutes.
If the temperature is too high wait a
few hours and check whether
the temperature has approached
the set value.
If the temperature is too low check
the temperature again the next day.
Displays
do not illuminate.
Power failure; the fuse
has been switched off;
the mains plug has not
been inserted
properly.
Connect mains plug. Check whether
the power is on, check the fuses.
The light
does not function.
The LED light
is defective.
See chapter “Light (LED)” section.
Appliance was open
too long.
Light is switched off
after approx. 10 min.
When the appliance is closed
and opened, the light is on again.
Bottom of the
refrigerator
compartment is wet.
The condensation
channel or drainage
hole are blocked.
Clean the condensation channel
and the drainage hole. See chapter
Cleaning the appliance. Fig.
3
The temperature in
the refrigerator com-
partment is too cold.
Temperature has been
set too low.
Increase the temperature.
Appliance is not
cooling, temperature
display and light
are lit.
Showroom mode is
switched on.
Hold down temperature selection
button fig.
2
/3 for 10 seconds until
an acknowledgement signal sounds.
After a short time check whether
your appliance is cooling.
Summary of Contents for KI12 Series
Page 79: ...1 2 C Alarm Super 1 2 3 4 5 Super Alarm...
Page 80: ...3 4 5 6 7 8...
Page 81: ...9...
Page 82: ...FD Nr E Nr...