• Whether the pressure switch controls properly or not? Please see the details of
switch adjustment.
NOISE OR DYSFUNCTION
• Whether the pipe is loose or not?
• Whether the pipe is bending that cause's transmission noise?
• Whether the pump feet are installed too loose or too tight?
• Whether three long screws on the pump head become loose or not?
• If the motor and pump head had been disassembled, do you know where the
noise come from, the motor or pump head?
PRESSURE SWITCH STARTS FREQUENTLY REASONS
• Pressure switch controls through pressure adjustment.
• The single nozzle works under the situation of the largest atomization.
11. DISPOSAL GUIDELINES