7
8. Fully depress the Trigger.
9. Turn the Fluid Knob clockwise until it reaches a natural
stopping point.
10. Release the trigger.
11. Tighten Collar on Fluid Knob to lock fluid adjustment
settings.
Air Adjustment
12. Attach Spray Gun to spray gun regulator. Use spray gun
regulator to measure airflow PSI.
13. Adjust the air supply pressure during operation with the
Trigger fully depressed and the Air Knob fully open.
If reducing air pressure for specific areas, use the Air Knob.
14. To fine-tune airflow, turn Air Knob clockwise to lessen airflow
pressure. Turn Air Knob counterclockwise to increase airflow
pressure.
Pattern Adjustment
15. Use the Pattern Knob to adjust the spray pattern.
Turn Pattern Knob counterclockwise (all the way open) to flatten
the spray pattern.
Turn it clockwise for a round spray pattern
- see Figure K: Pattern Adjustment.