background image

 

 

AIR SOURCE 

1.                        Never connect to an air source that is capable of exceeding 200 psi. Over     

pressurizing the tool may cause bursting, abnormal operation, breakage of the 
tool or serious injury to persons. Use only clean, dry, regulated compressed air 
at the rated pressure or within the rated pressure range as marked on the tool.

 

Always verify prior to using the tool that the air source has been adjusted to the rated air 
pressure or within the rated air-pressure range. 
2. Never use oxygen, carbon dioxide, combustible gases or any bottled gas as an air source 

for the tool. Such gases are capable of explosion and serious injury to persons. 

 
Specific Safety Instructions 

 
1. The warnings and precautions discussed in this manual cannot cover all possible conditions 

and situations that may occur. It must be understood by the operator that common sense 
and caution are factors which cannot be built into this product, but must be supplied by the 
operator. 

2. Only use with accessories rated to handle the forces exerted by this tool during operation. 

Other accessories not designed for the forces generated may break and forcefully launch 

pieces. 

3. Attach all accessories properly to the tool before connecting the air supply. A loose 

accessory may detach or break during operation. 

4. Obey the manual for the air compressor used to power this tool. 
5. Install an in-line shutoff valve to allow immediate control over the air supply in an emergency, 

even if a hose is ruptured. 

6. Do not lay the tool down until it has come to a complete stop. Moving parts can grab the 

surface and pull the tool out of your control. 

VIBRATION PRECAUTIONS 

 
This tool vibrates during use. Repeated or long-term exposure to vibration may cause 
temporary or permanent physical injury, particularly to the hands, arms, and shoulders. To 
reduce the risk of vibration-related injury: 
1. Anyone using vibrating tools regularly or for an extended period of time should first be 

examined by a doctor and then have regular medical check-ups to ensure medical 
problems are not being caused or worsened from use. Pregnant women or people who 
have impaired blood circulation to the hand, past hand injuries, nervous system disorders, 
diabetes, or Raynaud s Disease should not use this tool. If you feel any symptoms related 
to vibration (such as tingling, numbness, and white or blue fingers), seek medical advice 
as soon as possible. 

2. Do not smoke during use. Nicotine reduces the blood supply to the hands and fingers, 

increasing the risk of vibration-related injury. 

3. Wear suitable gloves to reduce the vibration effects on the user. 
4. Use tools with the lowers vibration when there is a choice. 
5. Include vibration-free periods each day of work. 

Summary of Contents for CT3073

Page 1: ...RINDER KIT CT3073 ORIGINAL INSTRUCTIONS Cannon Tools Limited Address 20 Station Road Rowley Regis West Midlands B65 0JU U K SAVE THESE INSTRUCTIONS AND PRECAUTIONS READ ALL PRECAUTONS AND INSTRUCTIONS...

Page 2: ...Directive based on its design and type as brought into circulation by us In case of alteration of the machine not agreed upon by us this declaration will lose its validity Product description AIR MIC...

Page 3: ...lting in the ignition of the dust or fumes 3 Keep bystanders children and visitors away while operating the tool Distractions are able to result in the loss of control of the tool Personal Safety 1 St...

Page 4: ...orrect tool for the application The correct tool will do the job better and safer at the rate for which the tool is designed 3 Do not use the tool if the switch does not turn the tool on or off Any to...

Page 5: ...h or break during operation 4 Obey the manual for the air compressor used to power this tool 5 Install an in line shutoff valve to allow immediate control over the air supply in an emergency even if a...

Page 6: ...nts and Controls INITIAL SETUP ASSEMBLY Air Supply WARNING To prevent serious injury from explosion use only clean dry regulated compressed air to power this tool Do not use oxygen carbon dioxide comb...

Page 7: ...Operation section for description of controls 4 Close the in line shut off valve between the compressor and the tool 5 Turn on the air compressor according to the manufacturer s directions and allow...

Page 8: ...and injury 2 Route the air hose along a safe route to reach the work area without creating a tripping hazard or exposing the air hose to possible damage The air hose must be long enough to reach the...

Page 9: ...ts off position before performing any inspection maintenance or cleaning procedures TO PREVENT SERIOUS INJURY FROM TOOL FAILURE Do not use damaged equipment If abnormal noise vibration or leaking air...

Page 10: ...5 Have qualified technician clean and lubricate mechanism Install in line filter in air supply as stated in Setup Air Supply 6 Replace all vanes Severe air leakage Slight air leakage is normal especi...

Page 11: ...NUT 13 BALL BEARING 2 COLLET 14 INTAKE PLATE 3 FRONTCOVER 15 SLEEVE 4 COLLET FONDATION 16 INTAKE STEELTUBE 5 BALLBEARING 17 HOSE PLUG 6 SPACER 18 PIN 7 LATERAL DISC 19 SLIDING KNOB 8 CYLINDER 20 0 RI...

Page 12: ...12 CANNON TOOLS LTD Add 20 station road Rowley Regis west midlands B65 0JU U K Made in China...

Reviews: