Tucker GmbH,
Mail / Post:
Max-Eyth-Str.1, 35394 Gießen, Germany
Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1227
120
10.3.8 E008 Primary Overcurrent Error
Fatal, meaning you have to power down to continue welding
Yes
Acknowledge, meaning the error will exist as long as the unit is powered on.
(Note, welding can continue while the error exists)
No
Description:
When a dangerous primary current is sensed (by means of the Current transformer
sensors in the back of the unit near the fan plenum), the control will quickly disable
the output of the power section to prevent damage. This should only happen due to
internal failures.
Likely problems or items to check - in order from most likely to least likely:
1. Replace the output board.
2. Replace the switch boards (both).
3. Replace the control boards.
E008
Summary of Contents for N800iTM