Tucker GmbH,
Mail / Post:
Max-Eyth-Str.1, 35394 Gießen, Germany
Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1227
122
10.3.10 E010 Capacitor Voltage Could Not Be Read
Fatal, meaning you have to power down to continue welding
No
Acknowledge, meaning the error will exist as long as the unit is powered on.
(Note, welding can continue while the error exists)
No
Description:
The voltage-to-frequency signal as provided by the switch boards
to the control board are not within a 'window' defined by the control board
(indicating that they are invalid, or caused by noise on the signal line).
Likely problems or items to check - in order from most likely to least likely:
1. Inspect V-F wiring from switch board to control board. Keep wiring away from
high power wires.
2. Eliminate possible sources of external electrical noise on the same circuit as this
welder.
3. Replace switch board.
4. Replace control board.
E010
Summary of Contents for N800iTM
Page 18: ......