10.3.13 E013 Weld Failed - Out of Tolerance
Fatal, meaning you have to power down to continue welding
No
Acknowledge, meaning the error will exist as long as the unit is powered on.
(Note, welding can continue while the error exists)
No
Description:
If the unit is configured to compare each weld results (Actual current, voltage, time,
etc) to a given weld 'target', it will display this error when the last weld is out of
the configured tolerance range. Change weld setup as appropriate, set a new
target, or disable this error as necessary.
Likely problems or items to check - in order from most likely to least likely:
Change weld setup as appropriate.
Configure new target. To do this, select F32 and hold the lock button.
Adjust tolerance (weld energy F35 or drop time F34)
E013