10.3.14 E014Warning-ColdPlunge-StudHitAfterCurrent Was
Shut Off
Fatal, meaning you have to power down to continue welding
No
Acknowledge, meaning the error will exist as long as the unit is powered on.
(Note, welding can continue while the error exists)
No
Description:
The gun coil was de-energized and the stud did not hit the molten pool before current
was hut off. This lends itself to cold welds. Adjustments should be made to the unit
settings to avoid this condition.
Re-configure drop time (F31). Perform a weld while viewing F31. The unit will
measure the new drop time and use it in weld timing.
Increase the short circuit on time (F2). This is extra assurance that even with varying
gun drop times, the current will stay on long enough to overcome the variation.