10.3.16 E016 Warning - Check Weld Cables and Connectors -
Press lock to clear
Fatal, meaning you have to power down to continue welding
No
Acknowledge, meaning the error will exist as long as the unit is powered on.
(Note, welding can continue while the error exists)
Yes
Description:
If a cable resistance target was saved using F55 and F56, upon each weld, the unit
will measure the weld cable resistance. If for any weld the resistance is outside of the
tolerance windo set by F56, this warning will be displayed. Press the
‘lock’ key to
clear the eroor while viewing the error in F1 (error display).
To remedy, periodically tighten connectors and inspect cables for any cause for
increased resistance. Cables will naturally increase as weld current heats them. If a
new cable resistance target is required, save it in F55 following a weld. A new target
is required when added or remo- ving cables.
Connectors
E016