Tucker GmbH,
Mail / Post:
Max-Eyth-Str.1, 35394 Gießen, Germany
Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1227
31
4.2.2
Connection of the Welding Cable
Symbol
Connection
Connection of the welding cable of the gun is effected by means
of the welding cable socket of the N800i which is marked with the
gun symbol.
It must be noted that procedurally safe operation of the system
can only be guaranteed when NS 40-B or NS 40 SL guns are
connected.
Cable Connection (X2)
Connect the welding cable plug of the gun to the welding cable
socket of the N800i.
The connection must be secured by a full “turn to the right” of
the welding cable plug!
4.2.3
Connection of the Control Cable
The control cable socket serves to take the control cable plug of the gun. The signals to
control the gun are transmitted via the control cable.
In keeping with the weld gun to be connected (type NS 40
‐
B or NS 40 SL), the
control cable socket of the welding unit is 4
‐
pole in design, some may be 2
‐
pole.
Symbol
Connection
Control Cable Connection (X1)
Pin 1: Gun coil (-)
Pin 2: Gun coil (+)
Pin 3: Start button of the gun (+)
Pin 4: Start button of the gun (-)
The connection must be secured by “screwing on” the control